![ABB FEP315 Original Instruction Download Page 13](http://html.mh-extra.com/html/abb/fep315/fep315_original-instruction_4407013.webp)
Device
designs
SM/FEX300/FEX500/FM/CSA-EN
FEX300, FEX500
EN - 11
3.4 Name
plate
3.4.1 Name plate for model with integral mount design (dual-compartment housing)
G006
29
1
2
3
4
5
6
7
8
9
1
0
11
12
1
3
14
15
1
6
17
1
8
19
2
0
21
Fig.
1 Model number (for more detailed information about
the technical design, refer to the data sheet or the
order confirmation)
2 Order
no.
3 Meter size and nominal pressure rating
4 Material:
Flange/lining/electrode
5 T
med
= max. permissible fluid temperature
T
amb
= max. permissible ambient temperature
6 Calibration value Qmax DN
7 Calibration value Ss (span)
Calibration value Sz (zero point)
8 Communications protocol of transmitter
9
Excitation frequency of sensor coils
10 Software version
11
Year of manufacture
12
CE mark
13
Serial number for identification by the manufacturer
14 Client-specific TAG number (if specified)
15 Protection type according to EN 60529
16
Supplementary information: EE = grounding
electrodes, TFE = partial filling electrode
17
Accuracy to which the unit was calibrated (e.g., 0.2%
of rate)
18
Version level (xx.xx.xx)
19 Label indicating whether the unit is subject to the
Pressure Equipment Directive (PED).
Information on the relevant fluid group.
Fluid group 1 = hazardous fluids, liquid, gaseous.
(Pressure Equipment Directive = PED).
If the pressure equipment is not subject to the
Pressure Equipment Directive 2014/68/EU, it is
classified in accordance with SEP (= sound
engineering practice) as per Art. 3 Para. 3 of the PED.
If no such information is present, it means that the
device does not claim to comply with the requirements
of the Pressure Equipment Directive 2014/68/EU.
Water supplies and connected equipment accessories
are classed as an exception in accordance with
guideline 1/16 of Art. 1 Para. 3.2 of the Pressure
Equipment Directive.
20
Ex mark according to FM (example)
21
Ex mark according to cFM (example)
IMPORTANT (NOTE)
Meters with 3A approval are labeled with an additional plate.
Summary of Contents for FEP315
Page 2: ......
Page 44: ...Appendix 42 EN FEX300 FEX500 SM FEX300 FEX500 FM CSA EN ...
Page 46: ...Appendix 44 EN FEX300 FEX500 SM FEX300 FEX500 FM CSA EN ...
Page 47: ......