Mechanical installation
23
3ADW000462R0301 DCS880 Hardware Manual e c
Recommended air entry / exit sizes in case of filters (IP22)
Terminal options for converter modules size H1 ... H5
There are different options to protect and connect the terminals of converter
modules size H1 ... H5.
Connection of H4 and H5 converter module DC terminals
In some cases it is beneficial to use lug bars for easy DC cable connection.
Size
Nominal converter current [A]
Air entry size [m
2
]
Air exit size [m
2
]
H1
20 ... 100
0.22
0.11
H2
135 ... 300
H3
290 ... 350
H3
405 ... 520
0.31
0.15
H4
590 ... 1000
H5
1190
0.22
0.11
H6
900 ... 2000
H7
1900 ... 3000
0.44
0.31
H8
2050 ... 5200
0.52
DC terminals of
D4 module
13
5
95
71
60
14
7.35
Id No.
Remark
3ADV280706P0001
right
3ADV280706P0002
left
Bottom view
Lug bars
of converter