Technical data
84
3ADW000462R0301 DCS880 Hardware Manual e c
Installation
Chaining a control panel
This figure shows how to chain a control panel to several units:
1. Inset the four stand offs into the intermediate cover.
2. Connect the patch cable between X13 on the
SDCS-CON-H01 and X13 on the SDCS-DPI-H01
adapter.
3. Plug the SDCS-DPI-H01 adapter onto the standoffs.
4. Connect the grounding cable at X1 and the ground-
ing standoff using the screw.
5. Connect the cables to the control panel / a thyristor
power controller using X10-2 and X10-1.
6. Attach the plastic cover.
7. Attach the front cover
SB_880_003_DPI-H_a.ai
Unit 1
(49.01 = 1)
X10-2
…
X10-1
X10-2 X10-1
X10-2 X10-1
S100 = OFF
S101 = OFF
Unit 2
(49.01 = 2)
S100 = OFF
S101 = OFF
Unit n (max. 32)
(49.01 = n)
S100 = ON
S101 = OFF
1)
The control panel terminates the bus at its end, so only the other end
of the bus must be terminated.
1)
SDCS-DPI-H01
SDCS-DPI-H01
SDCS-DPI-H01