Technical data
Input
Types
Sensor
Measuring range Error
Thermocouple Type J
−50...999
°
C
±
2
°
C
Thermocouple Type K
−50...1370
°
C
±
2
°
C
Thermocouple Type T
−270...400
°
C
±
2
°
C
Thermocouple Type E
−50...750
°
C
±
2
°
C
Thermocouple Type B
300...1800
°
C
±
3
°
C
Thermocouple Type R
0...1750
°
C
±
2
°
C
Thermocouple Type S
0...1750
°
C
±
2
°
C
Thermocouple Type N
−50...1300
°
C
±
2
°
C
Pt100 (DIN or JIS)
−200...400
°
C
±
0,4
°
C
Linear (−10...60 mV)
−1999...9999
±
0,05 %
Reference junction compensation
0.1 % of the ambient temperature
Correction of process variable
adjustable
Option
0/4...20 mA input
Outputs
Control relay
3 A / 240 V AC resistive load
Alarm relay
2 A / 240 V AC resistive load
Optional
continuous output 0/4...20 mA (maximum load 500
Ω
)
Display
Process variable
4-digit, red LED
Setpoint
4-digit, green LED
Green or red status LED for control or alarm relays
Power supply
90...264 V AC, 50/60 Hz
or
24 V UC (20...32 V AC/DC)
Power consumption
< 5 VA
Housing
Front
48
×
48 mm
Panel cutout
45
×
45 mm
Installation depth
86 mm
Mass
170 g
Type of protection
Front: IP 54
Electrical connection
with screw terminals (IP 00)
Enviromental conditions
Ambient temperature
−10...50
°
C
Storage and transportation temperature
−20...70
°
C
Relative humidity
0...90 %
no condensation
Insulation
20 M
Ω
(500 V DC)
Vibration immunity
10...55 Hz, 1 mm
Immunity to shock
20g
Electromagnetic compatibility / Safety
Interference immunity
according to EN 50 082-2
Interference emission
according to EN 55 011, class B
UL, CSA and CE certificate
CPU
Sampling rate
3 / s
18