7.2.5
Programming the travel times
Individual travel times can be programmed in operating mode "Programming (P)", to move the blind to a specific
intermediate position.
Programming procedure
1. Prior to programming, move the blind to the top end position.
2. Set operating mode "Programming (P)". See chapter "Changing the operating mode", page 15.
3. Move the blind down to the desired position with a long actuation of the operating surface.
An interim stopping of the blind is possible. All DOWN times are added and stored.
Note
If an extension unit is installed, this can also be used for moving the blind UP and DOWN. This
makes removing and re-attaching the control element during a change of operating mode
unnecessary.
4. Set the return travel pulse by moving the blind UP.
The slats of the blind are adjusted or the roller shutters are moved to the ventilation position via the return
travel pulse.
Before programming a return travel time, the DOWN time must amount to at least 10 seconds.
The return travel pulse starts with the initial UP movement of the blind. All subsequent travel times are added
during the up movement and subtracted during the DOWN movement and stored as a total return travel pulse.
The maximum return travel time is 25 seconds. Exceeding or dropping below this time is signalled with a stop
of the blind.
5. Exit operating mode "Programming (P)“ and set the original operating mode again. See chapter "Changing the
operating mode", page 15.
Programming is complete.
Check of programming
Preconditions:
•
Programming has been carried out correctly.
•
The blind is in the upper end position.
Sequence:
•
At a DOWN command the blind travels down at the programmed DOWN time.
•
The blind stops for 0.5 seconds.
•
The blind travels back to the top for the time of the programmed return travel pulse.
If the blind is not in the top end position, the DOWN command is carried out without the programmed intermediate
position. The blind travels down for 3 minutes.
Deleting programming
1. Switch into operating "Programming (P)" while the control element is pulled off.
2. Switch back to the previous operating mode.
Programming has been deleted