Operating Instructions
Busch-Jalousiecontrol
®
II
Installation and electrical
connection
Operating Instructions | 1473-1-8162
— 10 —
Pos: 37 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Überschriften (--> Für all e D okumente <--)/2. Ebene/M - O/M ontage i n Ver bindung mit anderen Ger äten @ 31\mod_1348832778182_15.docx @ 240455 @ 2233333333333333333333222 @ 1
6.2
Mounting in connection with other devices
Pos: 38 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Montage/Ti mer/M ontage mit anderen Ger äten - 6411 @ 30\mod_1348817071795_15.docx @ 240096 @ 33333333333333333333333333333333333333323311122333333332222222233422432443333 @ 1
6.2.1
Mounting with IR control element
•
In combination with IR control element 6066 the installation site must lie within the IR receiving range of 15 m.
•
The address of the IR control element is set on number "1" at the factory and can be changed via the address
wheel on the rear of the control element.
•
Observe the "IR receiving range" when addressing.
Note
The IR receiving range may vary due to extraneous light (e.g., sunlight, illumination).
6.2.2
Mounting with sensors
•
If the connection of a brightness sensor or glass break sensor is planned for flush-mounted insert 6411U/S-
101, consider the factory cable length of 2 m.
6.2.3
Mounting with extension units
•
The maximum cable length depends on the permissible ripple voltage of the auxiliary post inputs. The ripple
voltage, however, must not exceed 100 V. In practice this corresponds to a cable length of at least 100 m.
•
To prevent interference from switching processes of the blind drives, do not install the motor and extension
unit lines in the one cable or close to each other. The minimum distance is 5 cm.
•
To calculate the maximum number of devices to be operated in parallel in a safety circuit, observe the
following:
– The current consumption of the motors and the extension unit inputs
– The power consumption of the flush-mounted inserts
Pos: 39 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Überschriften (--> Für all e D okumente <--)/2. Ebene/M - O/M ontage @ 18\mod_1302615960458_15.docx @ 103424 @ 222222233333322222222222222222222222222222222222233333333 @ 1
6.3
Mounting
Pos: 40 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - 230 V @ 18\mod_1302606816750_15.docx @ 103308 @ 222222222222222222221122222233321223333322222222222222222222222222222223332222222222222243333 @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 230 V.
– Work on the 230V supply system may only be performed by authorised electricians!
– Disconnect the mains power supply prior to installation and/or disassembly!
Pos: 41 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Montage/alle Geräte/M ontage - U P-Dosen - D IN 49073-1 oder geeignetes Aufputzgehaeuse - Ohne Docvari abl e @ 25\mod_1340354979636_15.docx @ 219890 @ 2222123332223333332333222 @ 1
The flush-mounted insert must only be installed in flush-mounted wall boxes according to DIN 49073-1, Part 1, or
suitable surface-mounted housings.