Operating Instructions
Busch-Jalousiecontrol
®
II
Operation
Operating Instructions | 1473-1-8162
— 16 —
Pos: 53 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Überschriften (--> Für all e D okumente <--)/2. Ebene/A - F /Bedi enung in Verbi ndung mi t anderen Geräten @ 31\mod_1348832888297_15.docx @ 240498 @ 222233333222232111333333133 @ 1
7.2
Operation in connection with other devices
Pos: 54 /#Neustruktur#/Online-Dokumentation (+KNX)/Bedienung/Timer/Bedienung - 6411 @ 31\mod_1348824708779_15.docx @ 240442 @ 32222321113333322223333333311111111113333332 @ 1
The operation of the blind depends on the control element used and the use of the sensors.
When the control element is attached, the insert recognizes it automatically.
7.2.1
Operation via control element 6430
When operating mode N or M is set:
Button
Function
Actuation / Result
Blind UP
Blind DOWN
Brief press of the button:
- The blind travels to the top or bottom end position.
- A renewed brief press of the button stops the blind immediately.
Long button press:
- The blind travels up or down as long as the button is pressed.
When operating mode L is selected:
Button
Function
Actuation / Result
Blind UP
Blind DOWN
Brief press of the button:
- The blind travels to the top or bottom end position.
- A renewed brief press of the button stops the blind immediately.
Long button press:
- The blind travels up or down clocked as long as the button is pressed.
This causes the angle of the slats to be changed in stages.
7.2.2
Operation via IR control element 6066
Manual local operation as well as remote control via IR remote control 6010-25 takes place analogous to the
actuation of control element 6430. On IR control element 6066, the red LED flashes during sending operation.
7.2.3
Operation via extension units
All types of signal generators that supply a 230 V signal (no continuous signal) to extension unit inputs "1" and "2"
are suitable as extension units. The operation depends on the respective scope of functions of the extension unit
and the operating mode selected. The flush-mounted insert interprets the brief voltage pulses as a "brief actuation
(touch)" and the long voltage pulses as a "long actuation".
Priority of operation
•
The glass break sensor has the highest priority. When it is triggered, the extension unit inputs are
deactivated. The blind travels down and can only travel up again with a local operation.
•
Extension unit input "2" for UP has the second highest priority (Wind alarm). If voltage is applied to the input,
the blind travels up and remains up as long as voltage is applied to extension unit input "2".
•
All other operations have equal priority.