Operating Instructions
Busch-Jalousiecontrol
®
II
Installation and electrical
connection
Operating Instructions | 1473-1-8162
— 14 —
Pos: 47 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Anschluss/Ti mer /Anschluss H elligkeitssensor @ 31\mod_1348834080607_15.docx @ 240611 @ 33333322222222233333333333333222233333331111111111222222222222222 @ 1
6.4.1
Brightness sensor and glass break sensor
Note
The brightness sensor and the glass break sensor can only be used in connection with flush-
mounted insert 6411 U/S-101.
1. If necessary, remove the control element from the
flush-mounted insert.
2. Lever off the cover (3) carefully.
3. Pull the terminal block (1) out carefully.
4. Connect the brightness sensor and / or the glass break
sensor:
Ensure that the polarity of the cables is correct on the
brightness sensor.
Fig. 9: Connecting the sensor
S = Brightness sensor (light grey)
= Earth (white)
G = Glass break sensor
5. As a strain relief install the sensor cable with a small
loop in the loop compartment (2).
6. Do not extend the sensor cable, otherwise impairment
of functions can result.
For additional information on fixing the glass break sensor,
see the relevant operating manual.
Pos: 48 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenu+++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ 111111111111111113333333333333332222333333233333111222322222233333333333333333331111111111333333222233333 @ 1