![ABB Busch-Jaeger Busch-Jalousiecontrol II 6411 U-101 Operating Instructions Manual Download Page 15](http://html.mh-extra.com/html/abb/busch-jaeger-busch-jalousiecontrol-ii-6411-u-101/busch-jaeger-busch-jalousiecontrol-ii-6411-u-101_operating-instructions-manual_3022015.webp)
Operating Instructions
Busch-Jalousiecontrol
®
II
Operation
Operating Instructions | 1473-1-8162
— 15 —
Pos: 49 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Überschriften (--> Für all e D okumente <--)/1. Ebene/A - F /Bedi enung @ 11\mod_1279185541649_15.docx @ 83043 @ 11111111111111111111111133333113332222321112222 @ 1
7
Operation
Pos: 50 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Überschriften (--> Für all e D okumente <--)/2. Ebene/A - F /Betriebsarten @ 13\mod_1286276050737_15.docx @ 91535 @ 1111111111111111113333333333 @ 1
7.1
Operating modes
Pos: 51 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Bedi enung/Ti mer/Betriebsarten - 6411 @ 30\mod_1348734504324_15.docx @ 239735 @ 23333333333333333333333311111112112113111111111111122222221111132222223 @ 1
6411 U/S-101
6411 U-101
Fig. 10: Operating mode selector
Operating mode
Actuation / Function
Normal operation (N)
=factory setting
- A brief actuation (touch) of the operating surface triggers a travel command, which causes the blind to travel
to its upper or lower end position.
Another actuation interrupts the upward or downward travel.
- A long actuation of the operating surface causes the blind to travel UP/DOWN for the duration of the
actuation. If the actuation is longer than three minutes, the flush-mounted insert will switch itself off.
Slat operation (L)
- The brief actuation of the operating surface is identical to standard operation.
- A long actuation of the operating surface causes the blind to travel Up/Down clocked for the duration of the
actuation. If the actuation is longer than 3 minutes, the flush-mounted insert will switch itself off.
Central unit (Z)
- In this operating mode a flush-mounted blind control insert is used as central unit for additional blinds.
- At each actuation (brief or long) of the central unit, the blinds move to their end position.
- Programmed down-times of the extension units are executed.
Programming (P)
- Individual travel times of the blind can be programmed. E.g., if the blind is to travel automatically down to a
certain position and adjust the slats.
- The programmed travel time will become active after a switchover into a different operating mode only if
previously the blind travelled up as a result of a travel command (3 minutes). Only this will ensure that the
blind will travel to the desired position.
Awning function (M) /
only for 6411 U/S-101
- This operating mode is effective only in version 6411 U/S-101 with a brightness sensor connected.
- Without a brightness sensor this operating mode has no effect and is identical with standard operation (N).
Awning function:
- When the set brightness value is exceeded the blind travels down for 3 minutes or for a pre-programmed
down-time.
- The blind automatically travels up when the brightness value becomes too low only when the travel time
ensures that the sensor has an “unrestricted view” of the sun.
7.1.1
Changing the operating mode
Note
The operating mode can be changed when the electric voltage is connected.
1. Pull the control element from the flush-mounted insert with your hands.
See separate operating manual of the control element.
2. Turn the operating mode selector (adjusting wheel) to the desired operating mode.
The selected operating mode becomes active immediately.
3. Re-attach the control element to the flush-mounted insert.
Pos: 52 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenu+++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ 21133333333333333333332333321132222333333333323333311122223211111333322222222222 @ 1