20
AW T4 20 |
U N I V ER S A L 4 - W I R E , D UA L- I N P U T T R A N SM I T T ER | O I/AW T4 2 0 - EN R E V. B
…5 Electrical installation
Connecting EZLink sensors
NOTICE
Maximum length of cable from transmitter to sensor(s) –
refer to sensor Operating instruction.
Referring to Figure 16:
1
Align the pins in sensor cable connector
A
with the holes in
EZLink connector
B
and push the connectors together.
2
Turn nut
C
clockwise to secure the connectors together.
The transmitter detects the type of sensor connected
automatically.
NOTICE
When installing sensor extension cables, ensure the male
end (end with label) of the cable is installed towards the
transmitter.
Long cables
If cables are longer than 30 m (94 ft), or they are outside, the
following cables must be screened or contained in conductive
conduit:
• digital I/O
• analog outputs
• communication
Figure 16 Connecting the sensor EZLink connector(s)
A
B
C