![ABB ACSM1 Series Hardware Manual Download Page 58](http://html1.mh-extra.com/html/abb/acsm1-series/acsm1-series_hardware-manual_3346607058.webp)
Electrical installation
58
Connecting the control cables
Control connections to the JCU Control Unit
Notes:
*Total maximum current: 200 mA
The wiring shown is for demonstrative
purposes only. Refer to the
appropriate
Firmware Manual
for
default I/O assignments.
Further information of the usage of the
connectors and jumpers are given in
the text; more details are available in
the chapter
.
Wire sizes and tightening torques:
X2: 0.5 … 2.5 mm
2
(24…12 AWG).
Torque: 0.5 N·m (5 lbf·in)
X3, X4, X5, X6:
0.5 … 1.5 mm
2
(28…14 AWG).
Torque: 0.3 N·m (3 lbf·in)
X1
External power input
24 V DC, 1.6 A
+24VI
1
GND
2
X2
Relay output
250 V AC / 30 V DC
2 A
NO
1
COM
2
NC
3
X3
+24 V DC*
+24VD
1
Digital I/O ground
DGND
2
Digital input 1
DI1
3
Digital input 2
DI2
4
+24 V DC*
+24VD
5
Digital I/O ground
DGND
6
Digital input 3
DI3
7
Digital input 4
DI4
8
+24 V DC*
+24VD
9
Digital I/O ground
DGND
10
Digital input 5
DI5
11
Digital input 6
DI6
12
+24 V DC*
+24VD
13
Digital I/O ground
DGND
14
Digital input/output 1
DIO1
15
Digital input/output 2
DIO2
16
+24 V DC*
+24VD
17
Digital I/O ground
DGND
18
Digital input/output 3
DIO3
19
X4
Reference voltage (+)
+VREF
1
Reference voltage (–)
-VREF
2
Ground
AGND
3
Analogue input 1 (Current or voltage, selectable
by jumper J1)
AI1+
4
AI1-
5
Analogue input 2 (Current or voltage, selectable
by jumper J2)
AI2+
6
AI2-
7
AI1 current/voltage selection
J1
AI2 current/voltage selection
J2
Thermistor input
TH
8
Ground
AGND
9
Analogue output 1 (current)
AO1 (I)
10
Analogue output 2 (voltage)
AO2 (U)
11
Ground
AGND
12
X5
Drive-to-drive link termination
J3
Drive-to-drive link. See separate section below.
B
1
A
2
BGND
3
X6
Safe Torque Off. Both circuits must be closed for
the drive to start. See separate section below.
OUT1
1
OUT2
2
IN1
3
IN2
4
Control panel connection
Memory unit connection
X3
(4 × 4-pole,
1 × 3-pole)
X2
(3-pole)
X1
(2-pole)
X4
(1 × 7-pole,
1 × 2-pole,
1 × 3-pole)
X5
(3-pole)
X6
(4-pole,
orange)
J1
J3
J2
Order of terminal headers and
jumpers
T
Summary of Contents for ACSM1 Series
Page 1: ...ACSM1 Hardware Manual ACSM1 04 Drive Modules 0 75 to 45 kW...
Page 2: ......
Page 4: ......
Page 14: ...Table of contents 14...
Page 20: ...About this manual 20...
Page 24: ...The ACSM1 04 24...
Page 30: ...Planning the cabinet assembly 30...
Page 46: ...Planning the electrical installation 46...
Page 70: ...Maintenance 70...
Page 84: ...Technical data 84...
Page 90: ...Mains filters 90...
Page 96: ...Dimension drawings 96 Frame size A...
Page 97: ...Dimension drawings 97...
Page 98: ...Dimension drawings 98 Frame size B...
Page 99: ...Dimension drawings 99...
Page 100: ...Dimension drawings 100 Frame size C air cooled module...
Page 101: ...Dimension drawings 101...
Page 102: ...Dimension drawings 102 Frame size C for cold plate mounting...
Page 103: ...Dimension drawings 103 Frame size D air cooled module...
Page 104: ...Dimension drawings 104 Frame size D for cold plate mounting...
Page 106: ...Dimension drawings 106 Mains filters type JFI xx...
Page 108: ...Dimension drawings 108 Braking resistors type JBR xx...
Page 110: ...Dimension drawings 110...
Page 111: ......