Connector data
Connector pitch 5 mm, wire size 0.5 … 2.5 mm
2
(22…12 AWG)
Power supply (XPOW)
24 V (±10%) DC, 2 A
External power input.
Connector pitch 5 mm, wire size 0.5 … 2.5 mm
2
(22…12 AWG)
Relay outputs RO1…RO3 (XRO1…XRO3)
250 V AC / 30 V DC, 2 A
Protected by varistors
Connector pitch 5 mm, wire size 0.5 … 2.5 mm
2
(22…12 AWG)
+24 V output (XD24:2 and XD24:4)
Total load capacity of these outputs is 4.8 W (200 mA / 24 V)
minus the power taken by DIO1 and DIO2.
Connector pitch 5 mm, wire size 0.5 … 2.5 mm
2
(22…12 AWG)
Digital inputs DI1…DI6 (XDI:1…XDI:6)
24 V logic levels: “0” < 5 V, “1” > 15 V
R
in
: 2.0 kohm
Input type: NPN/PNP (DI1…DI5), PNP (DI6)
Hardware filtering: 0.04 ms, digital filtering up to 8 ms
DI6 (XDI:6) can alternatively be used as an input for a PTC sensor.
"0" > 4 kohm, "1" < 1.5 kohm.
I
max
: 15 mA (DI1…DI5), 5 mA (DI6)
Connector pitch 5 mm, wire size 0.5 … 2.5 mm
2
(22…12 AWG)
Start interlock input DIIL (XD24:1)
24 V logic levels: "0" < 5 V, "1" > 15 V
R
in
: 2.0 kohm
Input type: NPN/PNP
Hardware filtering: 0.04 ms, digital filtering up to 8 ms
Connector pitch 5 mm, wire size 0.5 … 2.5 mm
2
(22…12 AWG)
Digital inputs/outputs DIO1 and DIO2
(XDIO:1 and XDIO:2)
As inputs: 24 V logic levels: "0" < 5 V, "1" > 15 V.
R
in
: 2.0 kohm.
Filtering: 1 ms.
Input/output mode selection by para-
meters.
As outputs: Total output current from +24VD is limited to 200
mA
DIO1 can be configured as a frequency
input (0…16 kHz with hardware filter-
ing of 4 microseconds) for 24 V level
square wave signal (sinusoidal or other
wave form cannot be used). DIO2 can
be configured as a 24 V level square
wave frequency output. See the firm-
ware manual, parameter group 111/11.
R
L
DIOx
DIOGND
+24VD
Connector pitch 5 mm, wire size 0.5 … 2.5 mm
2
(22…12 AWG)
Reference voltage for analog inputs
+VREF and -VREF (XAI:1 and XAI:2)
10 V ±1% and -10 V ±1%,
R
load
1…10 kohm
Maximum output current: 10 mA
Connector pitch 5 mm, wire size 0.5 … 2.5 mm
2
(22…12 AWG)
Analog inputs AI1 and AI2
(XAI:4 … XAI:7).
Current input: -20…20 mA,
R
in
= 100 ohm
Current/voltage input mode selection
by jumpers
Voltage input: -10…10 V,
R
in
> 200 kohm
Differential inputs, common mode range ±30 V
Sampling interval per channel: 0.25 ms
Hardware filtering: 0.25 ms, adjustable digital filtering up to 8
ms
Resolution: 11 bit + sign bit
Inaccuracy: 1% of full scale range
136 The control unit
Summary of Contents for ACS880-304LC Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 304LC A019 diode supply modules Hardware manual ...
Page 2: ......
Page 4: ......
Page 30: ...30 ...
Page 34: ...34 ...
Page 46: ... Stage 1 Installation of common parts 46 Cabinet construction ...
Page 47: ... Stage 2 Module installation parts Cabinet construction 47 10 ...
Page 48: ... Stage 3 Liquid cooling system components 48 Cabinet construction ...
Page 49: ... Stage 4 AC and DC busbar installation Cabinet construction 49 10 ...
Page 50: ... Stage 5 AC and DC connection 50 Cabinet construction ...
Page 51: ... Stage 6 Cabinet fan and heat exchanger Cabinet construction 51 10 ...
Page 52: ... Stage 7 Shroud installation parts 52 Cabinet construction ...
Page 53: ... Stage 8 Door covers and explosion exhaust kit Cabinet construction 53 10 ...
Page 54: ...54 ...
Page 74: ...74 ...
Page 87: ...5 Maintenance 87 ...
Page 88: ...6 7 8 9 9 88 Maintenance ...
Page 92: ...92 ...
Page 108: ...108 ...
Page 118: ...118 ...
Page 140: ...Liquid cooled D8D module Dimensions in mm 1 mm 0 0394 in 140 Dimension drawings ...
Page 142: ...ZCU 14 control unit 142 Dimension drawings ...
Page 143: ...Support plate for ZCU 14 UDZKROH 0 GRZQ UDZKROH 0 GRZQ Dimension drawings 143 ...
Page 144: ...CIO 01 module 144 Dimension drawings ...
Page 152: ...152 ...