Read the manual before you work on the drive. You are expected to know the
fundamentals of electricity, wiring, electrical components and electrical schematic
symbols.
Categorization by frame size and option code
Some descriptions, instructions, technical data and dimensional drawings which
concern only a certain group of units are marked with the symbol of the frame size
(such as “D8D”, “2×D8D” etc.). The marking derives from the quantity and basic
construction of the modules that form a supply unit. For example, frame size “2×D8D”
indicates that the supply unit consists of two frame size D8D modules connected in
parallel.
The frame size is marked on the type designation labels. The frame size of each module
is also shown in the rating tables of chapter Technical data.
The instructions and technical data which concern only certain optional selections are
marked with option codes (such as +A019). The options included in the drive can be
identified from the option codes visible on the type designation label.
Use of component designations
Some device names in the manual include the component designation in brackets (for
example, [Q20]). This will help you to identify the components in the circuit diagrams
of the drive.
Terms and abbreviations
Description
Term/
Abbreviation
I/O module for controlling cooling fans
CIO
The part in which the control program runs.
Control unit
One section of a cabinet-installed drive. A cubicle is typically behind a door of
its own.
Cubicle
DC circuit between rectifier and inverter
DC link
Distributed drives communication system protocol
DDCS
Digital input
DI
Diode rectifier and related components enclosed in a metal frame or enclosure.
Intended for cabinet installation.
Diode supply module
Diode supply modules under control of one control board, and related com-
ponents.
Diode supply unit
Frequency converter for controlling AC motors
Drive
Diode supply unit
DSU
Electromagnetic compatibility
EMC
In this manual, external charging stands for drive charging circuit outside the
supply unit cubicle.
External charging
Optical DDCS communication module
FDCO
Diagnostics and panel interface board
FDPI
Rittal Flat-PLS, a busbar system for standard, commercially available flat
busbars
Flat-PLS
Physical size of the drive or power module
Frame, frame size
DC circuit between rectifier and inverter
Intermediate circuit
In this manual, internal charging stands for an ABB charging kit installed inside
the supply unit cubicle.
Internal charging
12 Introduction to the manual
Summary of Contents for ACS880-304LC Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 304LC A019 diode supply modules Hardware manual ...
Page 2: ......
Page 4: ......
Page 30: ...30 ...
Page 34: ...34 ...
Page 46: ... Stage 1 Installation of common parts 46 Cabinet construction ...
Page 47: ... Stage 2 Module installation parts Cabinet construction 47 10 ...
Page 48: ... Stage 3 Liquid cooling system components 48 Cabinet construction ...
Page 49: ... Stage 4 AC and DC busbar installation Cabinet construction 49 10 ...
Page 50: ... Stage 5 AC and DC connection 50 Cabinet construction ...
Page 51: ... Stage 6 Cabinet fan and heat exchanger Cabinet construction 51 10 ...
Page 52: ... Stage 7 Shroud installation parts 52 Cabinet construction ...
Page 53: ... Stage 8 Door covers and explosion exhaust kit Cabinet construction 53 10 ...
Page 54: ...54 ...
Page 74: ...74 ...
Page 87: ...5 Maintenance 87 ...
Page 88: ...6 7 8 9 9 88 Maintenance ...
Page 92: ...92 ...
Page 108: ...108 ...
Page 118: ...118 ...
Page 140: ...Liquid cooled D8D module Dimensions in mm 1 mm 0 0394 in 140 Dimension drawings ...
Page 142: ...ZCU 14 control unit 142 Dimension drawings ...
Page 143: ...Support plate for ZCU 14 UDZKROH 0 GRZQ UDZKROH 0 GRZQ Dimension drawings 143 ...
Page 144: ...CIO 01 module 144 Dimension drawings ...
Page 152: ...152 ...