Main circuit DC fuses
The IGBT supply unit has DC fuses at the output of each IGBT supply module.
Notes:
•
Fuses with higher current rating than the recommended ones must not be used.
•
Fuses from other manufacturers can be used if they meet the ratings and the melting
curve of the fuse does not exceed the melting curve of the fuse mentioned in the table.
DC fuses
ACS880-207LC-…
Type
Manufacturer
V
A
Qty
U
N
= 690 V
170M6546
Bussmann
1250
800
2
0360A-7
170M6546
Bussmann
1250
800
2
0400A-7
170M6547
Bussmann
1100
900
2
0450A-7
170M6548
Bussmann
1100
1000
2
0480A-7
170M6549
Bussmann
1000
1100
2
0560A-7
170M6500
Bussmann
1100
1250
2
0620A-7
170M6501
Bussmann
1100
1400
2
0700A-7
170M6501
Bussmann
1100
1400
2
0770A-7
170M6548
Bussmann
1100
1000
4
0930A-7
170M6549
Bussmann
1000
1100
4
1090A-7
170M6500
Bussmann
1100
1250
4
1180A-7
170M6501
Bussmann
1100
1400
4
1360A-7
170M6501
Bussmann
1100
1400
4
1500A-7
170M6500
Bussmann
1100
1250
6
1800A-7
170M6501
Bussmann
1100
1400
6
2020A-7
170M6501
Bussmann
1100
1400
6
2220A-7
170M6501
Bussmann
1100
1400
8
2670A-7
170M6501
Bussmann
1100
1400
8
2930A-7
170M6501
Bussmann
1100
1400
10
3320A-7
170M6501
Bussmann
1100
1400
12
3840A-7
170M6501
Bussmann
1100
1400
12
4360A-7
170M6501
Bussmann
1100
1400
16
5240A-7
170M6501
Bussmann
1100
1400
16
5810A-7
94 Technical data
Summary of Contents for ACS880-207LC
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 207LC IGBT supply units Hardware manual ...
Page 2: ......
Page 4: ......
Page 10: ...10 ...
Page 52: ...52 ...
Page 62: ...62 ...
Page 74: ...4 74 Maintenance ...
Page 79: ...4 5 6 Maintenance 79 ...
Page 96: ...Internal cooling circuit data See chapter Internal cooling circuit 96 Technical data ...
Page 98: ...98 Technical data ...
Page 99: ... 600 mm wide incoming cubicle or input cubicle Technical data 99 ...
Page 100: ... 1000 mm wide input cubicle 100 Technical data ...
Page 108: ...108 ...
Page 118: ...118 ...