478 Parameters
Specifies more hardware-related options that require
differentiated parameter defaults. See parameter
.
WARNING!
After switching any bits in this word,
recheck the values of the affected parameters.
-
0000b…0011b
Hardware options configuration word 2.
1 = 1
(Only visible with a BCU control unit)
Filters the list of drive/inverter types listed by parameter
.
All types
All types listed.
0
-3 (380-415V)
-3 (380…415 V) types listed.
1
-5 (380-500V)
-5 (380…500 V) types listed.
2
-7 (525-690V)
-7 (525…690 V) types listed.
3
(Only visible with a BCU control unit)
Defines the drive/inverter type if it consists of parallel-
connected modules.
If the drive/inverter consists of a single module, leave the
value at
.
Not selected
The drive/inverter does not consist of parallel-connected
modules, or type not selected.
0
[Drive/inverter type] Drive/inverter type consisting of parallel-connected modules.
-
Enables manual setting for the supply voltage limits with
parameters
Note:
Enabling Adjustable supply voltage limits overrides
limits based on
. This affects other soft limits in the drive
associated with the supply voltage.
WARNING!
An incorrect setting may cause the motor
to rush uncontrollably, or the brake chopper or resistor
to overload.
Disable
Adjustable supply voltage is disabled.
0
Enable
Adjustable supply voltage is enabled.
1
No.
Name/Value
Description
Def
/
FbEq16
Bit
Name
Information
0
Dual use
1 = Dual use active. For drives with N8200. (Allows higher
output frequencies and frequency reference limits.)
1
SynRM
1 = Synchronous reluctance motor used. Affects parameters
,
,
.
2
Salient PM
1 = Salient-pole permanent magnet motor used. Affects parameters
,
,
,
.
3…15
Reserved
Summary of Contents for ACS880-01 Series
Page 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 20: ...20 Introduction to the manual ...
Page 22: ...22 Using the control panel ...
Page 28: ...28 Control locations and operating modes ...
Page 146: ...146 Application macros ...
Page 502: ...502 Parameters ...
Page 606: ...606 Fault tracing ...
Page 662: ...662 Control chain diagrams ...