![ABB ACS880-01 Series Firmware Instructions Download Page 270](http://html.mh-extra.com/html/abb/acs880-01-series/acs880-01-series_firmware-instructions_2621270.webp)
270 Parameters
Defines the integration time of the speed controller. The
integration time defines the rate at which the controller output
changes when the error value is constant and the
proportional gain of the speed controller is 1. The shorter the
integration time, the faster the continuous error value is
corrected.
Setting the integration time to zero disables the I-part of the
controller. This is useful to do when tuning the proportional
gain; adjust the proportional gain first, then return the
integration time.
The integrator has anti-windup control for operation at a
torque or current limit.
The figure below shows the speed controller output after an
error step when the error remains constant.
2.50 s;
5.00
(
b1/b2)
Note:
This parameter is automatically set by the speed
controller autotune function. See section
(page
).
0.00 … 1000.00 s
Integration time for speed controller.
10 = 1 s
No.
Name/Value
Description
Def
/
FbEq16
K
p
× e
K
p
× e
%
e = Error value
Time
Gain = K
p
= 1
T
I
= Integration time > 0
T
D
= Derivation time = 0
Controller output
T
I
Summary of Contents for ACS880-01 Series
Page 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 20: ...20 Introduction to the manual ...
Page 22: ...22 Using the control panel ...
Page 28: ...28 Control locations and operating modes ...
Page 146: ...146 Application macros ...
Page 502: ...502 Parameters ...
Page 606: ...606 Fault tracing ...
Page 662: ...662 Control chain diagrams ...