Parameters 183
50.05
Fba ref2 modesel
Selects the fieldbus reference FBA REF2 scaling.
See parameter
Raw data
See parameter
0
Torque
See parameter
1
Speed
See parameter
2
50.06
Fba act1 tr src
Selects the source for fieldbus actual value 1 when parameter
is set to
Pointer
Value pointer setting (see
on page
).
-
50.07
Fba act2 tr src
Selects the source for fieldbus actual value 2 when parameter
is set to
Pointer
Value pointer setting (see
on page
).
-
50.08
Fba sw b12 src
Selects the source for freely programmable fieldbus status
word bit 28 (
bit 28 SW B28).
Const
Bit pointer setting (see
on page
). -
Pointer
50.09
Fba sw b13 src
Selects the source for freely programmable fieldbus status
word bit 29 (
bit 29 SW B29).
Const
Bit pointer setting (see
on page
). -
Pointer
50.10
Fba sw b14 src
Selects the source for freely programmable fieldbus status
word bit 30 (
bit 30 SW B30).
Const
Bit pointer setting (see
on page
). -
Pointer
50.11
Fba sw b15 src
Selects the source for freely programmable fieldbus status
word bit 31 (
bit 31 SW B31).
Const
Bit pointer setting (see
on page
). -
Pointer
51
51 FBA settings
Fieldbus adapter-specific settings.
51.01
FBA type
Displays the type of the connected fieldbus adapter module.
0 = Fieldbus module is not found, or it is not properly
connected, or parameter
is set to
,
1 = FPBA-xx PROFIBUS-DP adapter module, 32 = FCAN-xx
CANopen adapter module, 37 = FDNA-xx DeviceNet adapter
module
51.02
FBA par2
are adapter module-specific. For
more information, see the User’s Manual of the fieldbus
adapter module. Note that not all of these parameters are
necessarily visible.
-
…
…
…
…
51.26
FBA par26
See parameter
-
No.
Name/Value
Description
FbEq
Summary of Contents for ACS850 series
Page 1: ...ACS850 Firmware Manual ACS850 Standard Control Program...
Page 2: ......
Page 4: ......
Page 24: ...24 Start up...
Page 28: ...28 Control locations and operating modes...
Page 252: ...252 Fieldbus control...