ACS550 User’s Manual
57
Start-Up
2003
MAX
CURRENT
0… 1.8 * I
2hd
0.1 A
1.8 * I
2hd
9
2005
OVERVOLT
CTRL
0 =
DISABLE
, 1 =
ENABLE
1
1
2006
UNDERVOLT
CTRL
0 =
DISABLE
, 1 =
ENABLE
(
TIME
),
2 =
ENABLE
1
1
2007
MINIMUM
FREQ
-500…500 Hz
0.1 Hz
0 Hz
9
2008
MAXIMUM
FREQ
0…500 Hz
0.1 Hz
01: 50 Hz / U1: 60 Hz
9
2013
MIN
TORQUE
SEL
0…7, -1…-6
1
0
2014
MAX
TORQUE
SEL
0…7, -1…-6
1
0
2015
MIN
TORQUE
1
-600.0%…0%
0.1%
-300.0%
2016
MIN
TORQUE
2
-600.0%…0%
0.1%
-300.0%
2017
MAX
TORQUE
1
0%…600.0%
0.1%
300.0%
2018
MAX
TORQUE
2
0%…600.0%
0.1%
300.0%
Group 21: Start/Stop
2101
START
FUNCTION
1…5
1
1
9
2102
STOP
FUNCTION
1 =
COAST
, 2 =
RAMP
1
1
2103
DC
MAGN
TIME
0…10 s
0.01 s
0.3 s
2104
DC
CURR
CTL
0, 2
-
0
9
2105
DC
HOLD
SPEED
0…360 rpm
1 rpm
5 rpm
2106
DC
CURR
REF
0%…100%
1%
30%
2107
DC
BRAKE
TIME
0…250 s
0.1 s
0 s
2108
START
INHIBIT
0 =
OFF
, 1 =
ON
1
0
9
2109
EM
STOP
SEL
0…6, -1…-6
1
0
2110
TORQ
BOOST
CURR
15…300%
1
100%
Group 22: Accel/Decel
2201
ACC
/
DEC
1/2
SEL
0…7, -1…-6
1
5
2202
ACCELER
TIME
1
0.0…1800 s
0.1 s
5 s
2203
DECELER
TIME
1
0.0…1800 s
0.1 s
5 s
2204
RAMP
SHAPE
1
0=
LINEAR
; 0.1...1000.0 s
0.1 s
0.0 s
2205
ACCELER
TIME
2
0.0…1800 s
0.1 s
60 s
2206
DECELER
TIME
2
0.0…1800 s
0.1 s
60 s
2207
RAMP
SHAPE
2
0=
LINEAR
; 0.1...1000.0 s
0.1 s
0.0 s
2208
EM
DEC
TIME
0.0…1800 s
0.1 s
1.0 s
2209
RAMP
INPUT
0
0…6, -1…-6
1
0
Group 23: Speed Control
2301
PROP
GAIN
0.00…200.0
0.01
10
2302
INTEGRATION
TIME
0…600.00 s
0.01 s
2.5
2303
DERIVATION
TIME
0…10000 ms
1 ms
0
2304
ACC
COMPENSATION
0…600.00 s
0.01 s
0
2305
AUTOTUNE
RUN
0 =
OFF
, 1 =
ON
1
0 (
OFF
)
Group 24: Torque Control
2401
TORQ
RAMP
UP
0.00…120.00 s
0.01 s
0
2402
TORQ
RAMP
DOWN
0.00…120.00 s
0.01 s
0
Group 25: Critical Speeds
2501
CRIT
SPEED
SEL
0 =
OFF
, 1 =
ON
1
0
2502
CRIT
SPEED
1
LO
0…30000 rpm / 0…500 Hz
1 rpm / 0.1 Hz 0 rpm / 0 Hz
Code
Name
Range
Resolution
Default
User
S