EN
23
Maximum motor cable lengths
To comply with European EMC regulations, the motor cable length
has to be limited as specified in the table below. The shorter the
motor cable, the lower the noise emissions to the supply line and
the environment.
1) Switching frequency can be selected with the DIP switch. See
page
2) Applicable for conducted emissions only.
3) Applicable for conducted and radiated emissions.
Protections
Overvoltage, undervoltage, output short circuit, overcurrent,
analogue input loss, motor overload, inverter overload.
Distribution networks isolated from earth
Drives with built-in EMC filter, or ACS55-IFAB-01 external input
filter must not be used in a floating network or in a high impedance
earthed industrial distribution network.
Environmental information
A product to be disposed contains valuable raw material that
should be recycled, thus preserving energy and natural resources.
Instructions for disposal are available from ABB sales and service
companies.
Liability limits
The manufacturer is not responsible for:
• Any costs resulting from a failure if the installation,
commissioning, repair, alteration or ambient conditions of the
drive do not fulfil the requirements specified in the
documentation delivered with the unit and other relevant
documentation.
• Units subjected to misuse, negligence or accident.
• Units comprised of materials provided or designs stipulated by
the purchaser.
In no event shall the manufacturer, its suppliers or subcontractors
be liable for special, indirect, incidental or consequential damages,
losses or penalties.
If you have any question concerning your ABB drive, please
contact the local distributor or ABB office. The technical data,
information and specifications are valid at the time of printing.
The manufacturer reserves the right to modifications without prior
notice.
Built-in EMC filter
External EMC filter
ACS55-01E-
ACS55-IFAB-01 and
ACS55-01N/E
Converter type
5 kHz
16 kHz
1)
5 kHz
16 kHz
1)
EN61800-3, First environment, unrestricted distribution
2)
01A4-2, …, 02A2-1
10 m
3 m
-
-
07A6-2, …, 09A8-2
10 m
3 m
-
-
EN61800-3, First environment, restricted distribution
3)
01A4-2, …, 02A2-1
10 m
10 m
30 m
10 m
07A6-2, …, 09A8-2
20 m
10 m
-
-
EN61800-3, Second environment
3)
01A4-2, …, 02A2-2
10 m
10 m
50 m
10 m
04A3-2
10 m
10 m
75 m
10 m
01A4-1, …, 02A2-1
10 m
10 m
50 m
10 m
07A6-2, …, 09A8-2
30 m
10 m
-
-
Summary of Contents for ACS55
Page 2: ......
Page 4: ...4 ...
Page 5: ...EN 5 User s Guide for type ACS55 AC Drives from 0 18 to 2 2 kW English EN ...
Page 25: ...DA 25 Brugermanual for type ACS55 AC drev fra 0 18 til 2 2 kW Dansk DA ...
Page 45: ...DE 45 Deutsch DE Betriebsanleitung für ACS55 Frequenzumrichter von 0 18 bis 2 2 kW ...
Page 65: ...ES 65 Español ES Guía del usuario para Accionamientos de CA de tipo ACS55 de 0 18 a 2 2 kW ...
Page 85: ...FI 85 Käyttäjän opas ACS55 taajuusmuuttajat 0 18 2 2 kW Suomi FI ...
Page 125: ...IT 125 Italiano IT Manuale utente per convertitori di frequenza in c a ACS55 da 0 18 a 2 2 kW ...
Page 146: ...146 IT ...
Page 147: ...NL 147 Nederlands NL Gebruikershandleiding voor type ACS55 AC omvormers van 0 18 tot 2 2 kW ...
Page 188: ...188 PT ...
Page 209: ...SV 209 Användarhandledning för frekvensomriktare ACS55 från 0 18 till 2 2 kW Svenska SV ...
Page 229: ...CN 229 用户手册 ACS55 交流传动 0 18 至 2 2 kW 中文 CN ...
Page 249: ...KR 249 사용자 메뉴얼 ACS55 AC 드라이브 0 18 2 2 kW 한국어 KR ...
Page 269: ......