11.03
REF1 SELECT
COMM
Fieldbus interface as source for speed
reference
16.04
FAULT RESET
SEL
COMM
Fieldbus interface as source for fault
reset
(11.05)
REF1 MAX
[Scale max]
Max speed/frequency scaling value
(used in function block/visualization input
SPEED_REF_MAX
). Must be less or
equal to drive parameter max
speed/frequency.
ACS550 More actual values or parameters to be read from drive to PLC
(optional)
Parameter
Description
Setting
Comment
51.06,
51.08…
51.20
Actual value or
parameter of drive
GGii
GG = parameter group, ii = parameter index
Example, 0104 = actual current; 0145 = motor temp
51.27
FBA PAR
REFRESH
REFRESH
Updates fieldbus settings (group 51)
ACS550 More parameters to be written from PLC to drive (optional)
Parameter
Description
Setting
Comment
51.05,
51.07…
51.19
Parameter of drive
GGii
GG = parameter group, ii = parameter index
Example, 2202 = acceleration time 1
51.27
FBA PAR
REFRESH
REFRESH
Updates fieldbus settings (group 51)