![ABB ACS2000 AFE 1MVA User Manual Download Page 38](http://html.mh-extra.com/html/abb/acs2000-afe-1mva/acs2000-afe-1mva_user-manual_3276038.webp)
CHAPTER 2 – POWER ELECTRONICS AND CABINET FEATURES
38
2.3.4 DC link
The DC link consists of the charging unit (not
shown), the capacitor
(1)
, and the grounding
switch
(2)
.
Charging unit
Charging
The unit charges the DC-link capacitor and the
phase capacitors before the MCB is closed to con-
nect the drive to the main power supply. Thus,
excessive inrush currents are prevented.
The charging unit is fed from the auxiliary power
supply and charges the DC link and the phase
capacitors to 90% of the steady state voltages.
The charging sequence is started by pressing the
SUPPLY ON pushbutton on the control compart-
ment door. After the charging sequence has fin-
ished, the charging unit is disconnected from the
medium voltage circuit, the MCB is closed and the
DC link reaches its nominal level.
Stand-by mode
Once the DC link is charged, it is possible to keep
the drive in this state to facilitate a more rapid
start-up procedure. The losses during stand-by
mode are approx. 1% of the nominal power and are
caused from small losses from the AFE, the INU,
and the auxiliaries.
Discharging
Discharging is initiated by pressing the
SUPPLY
OFF
pushbutton on the control compartment door.
The DC-link capacitors then discharge via the IFU.
The energy stored in the DC link is dissipated in the
parasitic resistors of the power part of the drive.
When the DC-link voltage has decreased below a
quarter of the DC-link voltage, the capacitors in the
phase modules start to discharge as well.
—
References
—
2-7 DC-link
—
1
1
2
Summary of Contents for ACS2000 AFE 1MVA
Page 6: ...170 Replacing filter mats 171 Phase modules location 171 Phase module Dimensions and weight ...
Page 8: ...Terms trademarks related documentation ...
Page 13: ...13 ACS2000 AFE 1MVA UM 3BHS297030 ZAB E01 REV J ...
Page 14: ...General information on manual and drive ...
Page 19: ...19 ACS2000 AFE 1MVA UM 3BHS297030 ZAB E01 REV J ...
Page 20: ...Important note on main circuit breaker ...
Page 48: ...Chapter 3 Control system 49 Overview 50 Main components 54 I O interfaces ...
Page 67: ...67 ACS2000 AFE 1MVA UM 3BHS297030 ZAB E01 REV J ...
Page 77: ...77 ACS2000 AFE 1MVA UM 3BHS297030 ZAB E01 REV J ...
Page 83: ...83 ACS2000 AFE 1MVA UM 3BHS297030 ZAB E01 REV J 5 1 3 2 1 4 A B C E D ...
Page 85: ...85 ACS2000 AFE 1MVA UM 3BHS297030 ZAB E01 REV J ...
Page 113: ...113 ACS2000 AFE 1MVA UM 3BHS297030 ZAB E01 REV J ...
Page 114: ...Commissioning check list ...
Page 149: ...149 ACS2000 AFE 1MVA UM 3BHS297030 ZAB E01 REV J ...
Page 176: ......