2TLC172296M0201
Rev A
4
www.abb.com/jokabsafety
2015-03-20
Receiver cable for muting, M12-5 connector
Pin
Wire
1
Function
Connection to
1
Brown
Supply
24 VDC
2
White
MUTING2
Muting sensor
Shall be high in presence of object
3
Blue
Supply
0 V
4
Black
MUTING1
Muting sensor
Shall be high in presence of object
5
Grey
Not used
-
1
Colours according to ABB Jokab Safety standard cable
Receiver, cable for blanking, M12-C02PT6RB
Pin
Wire
1
Function
Connection to
1
Brown
Supply
+24 VDC
2
Blue
Supply
0 V
3
White
RESET/
ACKNOWLEDGE
/ALIGN
Auto. Reset with no function
Not connected
Auto. Reset with Acknowledge
function or Alignment mode
NO contact to +24 VDC
Manual Reset
NO contact to +24 VDC
4
Green
TEACH IN
If "Teach-in" of blanking zone is to be
used
NO contact to +24 VDC
5
Pink
OSSD 2
Safety control module for example
6
Yellow
EDM
Function used/activated
NC contact of a force guided relay
Function not used/deactivated
Not connected
7
Black
Not used
8
Grey
OSSD 1
Safety control module for example
9
Red
TOLERANCE
Activate the "Tolerance of fixed
blanking" function
NO contact to +24 VDC
10
Violet
LAMP
Lamp between output and
+24 VDC
- ON when Blanking activated.
- Flashing when Blanking error like
one more beam blanked than
configured for example.
11
Grey-pink Not used
12
Red-blue
EARTH
Earth
1
Colours according to ABB Jokab Safety standard cable