![ABB 2TLA022303R0100 Excerpts From The Instruction Manual Download Page 15](http://html.mh-extra.com/html/abb/2tla022303r0100/2tla022303r0100_excerpts-from-the-instruction-manual_5128015.webp)
2TLC172296M0201 Rev A
15
www.abb.com/jokabsafety
2015-03-20
Technical data
Manufacturer
Address
ABB JOKAB SAFETY
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden
Electrical data
Power supply (Vdd):
+24 VDC ± 20 %
Unit current draw (TX):
3 W max
Unit current draw (RX):
5 W max (without load)
Outputs:
2 PNP
Short-circuit protection:
1.4 A max
Output current:
0.5 A max / each output
Output voltage
– status ON:
Vdd
–1 V min
Output voltage
– status OFF:
0.2 V max
Capacitive load
2.2 µF @ +24 VDC max
Response times:
See table below
Recovery time:
Typically 100 ms ̶ Recovery Time may be longer if both first
and last beams are interrupted.
Protected height:
300...1800 mm
Electrical protection:
Class III - use SELV/PELV
Current for External Lamp:
20 mA min; 300 mA max
Connections:
M12 12-poles + M12 5-poles for receiver (muting models)
M12 12-poles for receiver (blanking models)
M12 5-poles for transmitter (for both models)
Cables length (for power supply):
50 m. max
Optical data
Emitting light (λ):
Infrared, LED (950 nm)
Resolution:
14 - 30 mm
Operating distance:
0.2…20 m for 30 mm
0.2…7 m for 14 mm
Ambient light rejection:
According to IEC-61496-2:2013
Mechanical and environmental data
Operating temperature:
0…+ 50 °C
Storage temperature:
-
25…+ 70 °C
Temperature class:
T6
Humidity:
15…95 % (no condensation)
Mechanical protection:
IP65 (EN 60529: 2000)
Vibrations:
Width 0.35 mm, Frequency 10…55 Hz
20 sweep per axis, 1octave/min (EN 60068-2-6:2008)
Shock resistance:
16 ms (10 G) 103 shocks per axis (EN 60068-2-29: 2008)
Housing material:
Painted aluminium (yellow RAL 1003)
Front side material:
PMMA
Caps material:
PBT Valox 508 (pantone 072C)
Cover material:
PC LEXAN
Weight:
1.35 kg per linear meter for single unit