2TLC172296M0201
Rev A
12
www.abb.com/jokabsafety
2015-03-20
Receiver
P
W
R
O
S
S
D
E
D
M
A
C
M
LEVEL
AOPD mode
Status
LED configuration
Action
Alignment
Not aligned
See the instruction manual
paragraph “Alignment
procedure”.
FIRST aligned
See the instruction manual
paragraph “Alignment
procedure”.
LAST aligned
See the instruction manual
paragraph “Alignment
procedure”.
Minimum alignment
signal level
See the instruction manual
paragraph “Alignment
procedure”.
Maximum alignment
signal level
See the instruction manual
paragraph “Alignment
procedure”.
Normal operation
Manual Reset Only
Interlock
Free beams
AOPD waiting for Reset.
Push the RESET button.
Interlock
Interrupted beams
Free the detection zone and
push the RESET button.
Normal operation
OSSD ON
(maximum alignment)
OSSD OFF
Code 1
OSSD OFF
Code 2
OSSD OFF
No code
Signal level on the
beams
None
Insufficient
Low
Good
Best
EDM activated