TABLE 7-4. BASIC METER PARTS (REF: FIGURE 7-1)
KEY QTY
DESCRIPTION
SIZE, mm
PART NUMBER
1
2
3
4
5
6
7
8
9
10A
10B
11
12
13
14
15A
15B
16
17
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
1
1
1
2
2
2/4
-
2
2
1
1
1
2
6
2
2
2
1
1
1
5
5
1
6
6
6
1
1
1
1
2
2
1
1
1
1
1
2
METER BODY:SEE NOTE 1
O-RING:Converter Base Seal
BOLT, Self Sealing
LOCTlTE, Type 271
SCREW, Flat Hd: 1/4-20 x 1/2’
WASHER, Csk: M6
SCREW, Flat Nd:
#8-32 x 1/4"
#10-32 x 5/16"
LOCKWASHER, Csk, Ext.Tooth
#8
#10
BASE,Converter
FILTER CAPACITOR ASSY (RFI), 100 pF, 120 VAC
FILTER CAPACITOR ASSY (RFU), 1000 pF, 500 VDC
GROUND STRAP
SCREW, Pan Hd: #6-32 x 1/4"
LOCKWASHER, Ext. Tooth: #6
SEAL RING, Cover
PRIMARY BOARD, Converter Base (CMF)
ADAPTOR BOARD (for remote converter)
SCREW, Pan Hd: #4-40 x 1/4’
LOCKWASHER, Ext. Tooth: #4
COVER, Converter Base:
w/o Window
with
Window
SCREW, Pen Hd: #10-32 x 3/4"
LOCKWASHER, Ext Tooth: #10
O-RING, Screw Retainer
COVER, Customer Connection Box
PC BOARD, Customer Connection Box
SEAL RING, Customer Connection Box
O-RING, Connection Box to Converter
LOCKWASHER, Ext Tooth: 1/6"
SCREW, Hex Soc Hd: 1/4-20 x 7/8"
CUSTOMER CONNECTION BOX:
PIPE PLUG: 1/2" NPT SEE NOTE 2
FITTING, PipeSEE NOTE2
GROMMETSEE NOTE 2
FITTING,PipeSEE NOTE 2
GASKET,See TABLE 7-3
3 - 25
40 - 50
80
100
3 - 25
40 - 50
3 - 25
40 - 50
3 - 25
40 - 50
80
100
N/A
101A927U01
101A937U01
101A922U01
101A927U01
091B022U01
145A016U02
032B008T10
85G027KU05
002K004T10
002L005T10
085M008V11
085M010V11
610B249U03
610B249U04
610B249U05
610B249U06
C160C102U01
160C055U01
355A422U01
006H004T10
085H006V11
101A834U01
686B623U01
686B630U01
006H004T10
085H004V11
379D358U01
D612A083U01
006L012T10
085D010T10
333C596U01
C379D371U01
C686B624U01
101A825U01
101A001U08
085H416T10
038B014T10
C323D416U02
112A352U22
364D297U01
368D145R90
364D257U01
NOTES:
1. Meter body (Key 1) is a welded assembly end is not a repairable item. The manufacturer maintains a repair/exchange
program so that the entire meter or the Signal Converter alone, can be replaced with a minimum of down time; contact
your local factory field office for details. To order specify either a new or repair/exchange meter or Signal Converter, as
required. ALL correspondence should reference the complete instrument model number and serial number.
2. Parts are supplied with signal cable, when specified.
3. Mounting hardware and gaskets (supplied by the manufacturer) are selected according to meter size.
4. The Primary CMF Board is not interchangeable, see procedure 6.3.3 in MAINTENANCE section. It is suggested that
the user return the Magnetic Flowmeter to the factory for repair and calibration, or consult a factory service representative
for assistance.
10D1476 K-MAG MAGNETIC FLOWMETER INSTRUCTION MANUAL