2.8.2 Customer connection on robot
Location of customer connection
For the connection of extra equipment to the robot, cables and air hose are
integrated into the robot´s cabling, and there can be two UTOW71210SH06 and
one UTOW71626SH06 connector on the front part of the upper arm.
Note
The maximum leakage current for attached equipment must not exceed 10mA.
The customer connections are located on the robot as shown in the figure.
Customer connections on upper arm
A
B
C
D
xx2000001659
R2.PROC1
A
Air M16x1.5
(24° cone sealing)
R2.ETHERNET
i
B
R2.CP or R2.CBUS
C
R2.CS or R2.CP/CS
D
i
Use a straight ethernet connector. Using an angled connector causes a collision risk with R2.CP,
R2.CBUS or R2.CP/CS.
Continues on next page
Product manual - IRB 4600
99
3HAC033453-001 Revision: Y
© Copyright 2009-2021 ABB. All rights reserved.