Defining the parameter in the IRC5 software
The value of the system parameters that define the mounting angle must be
redefined when changing the mounting angle of the robot. The parameters belong
to the type
Robot
, in the topic
Motion
.
How to calculate a new value is detailed in
Mounting angles and values on page 59
The system parameters are described in
Technical reference manual - System
parameters
.
The system parameters are configured in RobotStudio or on the FlexPendant.
62
Product manual - IRB 1520
3HAC043435-001 Revision: L
© Copyright 2012-2020 ABB. All rights reserved.
2 Installation and commissioning
2.3.5 Setting the system parameters for a suspended or tilted robot
Continued