Note
Action
xx1800000171
Reconnect all connectors to the push button
unit.
Be careful not to damage the sockets or pins.
Make sure the connector and its locking arms
are snapped down properly.
3
Maximum tightening torque: 5 Nm.
xx1100000345
Fit the push button unit to the serial measure-
ment unit in the robot base and secure with
the two hexagon nuts.
4
Verify that the robot cabling is positioned
correctly, according to previously taken pic-
ture/notes.
WARNING
Screened cables must not get in contact with
the brake release board after installation.
Eliminate all risks of contact between
screened cables and the brake release board.
5
Check the
gasket
of the base cover. Replace
it if damaged.
6
Continues on next page