xx0600002777
Refit the centering piece (B) to the push but-
ton unit in order to align it vertically.
Also make sure that the unit is correctly
aligned sideways: the measurements x1 and
x2 in the figure to the right should not differ
more than 1 mm from each other!
5
Art. no. for the centering piece is specified
in
Required equipment on page 216
xx1100000316
Push the plate for connector (with SMB and
push button units fitted) carefully into the
base. Be careful not to damage any of the
components or cable harness in the process!
6
xx1100000329
Secure the plate for connector with its attach-
ment screws.
7
Continues on next page
220
Product manual - IRB 1520
3HAC043435-001 Revision: L
© Copyright 2012-2020 ABB. All rights reserved.
4 Repair
4.5.2 Replacing the serial measurement unit
Continued