roof structure, support bars or scaffolding, next to the wall. Suspension is done through the
burner combination hangers and
fastening eye
.
EXAMPLE OF HANGER ARRANGEMENT
4.
GAS CONNECTION
The appliance can only be used with the gas type specified on the nameplate.
If the gas supply pressure exceeds 60 mbar, a pressure regulator has to be used. The pressure
regulator can be installed individually for each appliance or centrally. A gas filter is advised to
be installed for thepressure regulator to prevent clogging which might be caused by the
deposits that can occur in the pipes even if they are blown out. The connection to the gas
pipeline should be made from above or from the side as connecting from below enables the
accumulation of contamination.
The thermal expansion of the tube radiant heater has to be taken into consideration when
connecting the gas supply, therefore a flexible hose enabling an expansion of 100 mm should
be used. The tube should not be twisted during installation. Connection is made directly to the
½” connector with external thread. A cock has to be installed before the connecting hose.
4.1
OPERATIONS TO BE DONE
-
GAS PIPELINE CLEANING
9
Summary of Contents for IT-DR OMEGA
Page 12: ...12 ...