Technical Specifications
231
OpenCom 150
System data
Mains power supply
230 V ~ 50 Hz
Rated power
160 VA
Safety class
2
Permissible temperatures, stationary,
weatherproofed
+5 °C to +40 °C
Dimensions
Wall version:
396 x 390 x 100 mm (W x H x D)
Rack version:
– Width: 19-inch panel with flange for
mounting in installation cabinet
– Height: 3 U
– Depth: approx. 340 mm
Weight (system only)
Wall version: 3.2 kg
Rack version: 7.8 kg
S
0
ports
Euro ISDN switchable (S
0
external /
S
0
internal) for basic access,
DSS1 protocol, or for ISDN terminals,
DSS1 protocol
Possible interface cards:
– 4 x S
0
– 2 x S
0
and 6 x U
pn
– 2 x S
0
and 6 x a/b
– Supply voltage
40 V ± 10%
– Supply power
2 VA for internal
– Range
150 m internal
U
pn
ports
for system terminals and RFP 22 / 24
DECT base stations
Possible interface cards:
– 4 x U
pn
– 8 x U
pn
– 2 x S
0
and 6 x U
pn
– Supply voltage
40 V ± 10%
– Supply power
3 VA per U
pn
bus
– Range
1,000 m