16
RZ Series Feature String Nomenclature
G
E
N
M
JR
E
V
S
IZ
E
S
E
R
IE
S
M
N
R
E
V
V
L
T
A1
A2
A3
A4
A5
B1
B2
B3
B4
B5
1
2
3A
3B
3C
3D
3
E
4A
4B
4C
5A
5B
5C
5D
5E
6A
6B
6C
6D
6E
7
8
9A
9B
9C
9D
RZ A - 145 - D 0 - 3 - C A B 0 A
-
0 0 0 0 0 :
N 0 - A A
K
A Q - J 0 0 - B F T 0 M - 0 0 0 0 0 - Q F - A 0 A A
- 0 0
-
M 0 - C - 0 0 0 - 8 0 - D A 0 B - 0 0 - 0 0 0 - A B E Q 0 A - E 0 0 0 0 0 - 0 0 0 0 0 D B
10
A
10
B
11A
11B
12
13A
13B
13C
14
15
16A
16B
16C
16D
17A
17B
18A
18B
18C
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
1: UNIT ORIENTATION
E = Draw Through SA Fan, Walk-in Vestibule, Left
Side Access
F = Draw Through SA Fan, Walk-in Vestibule, Right
Side Access
G = Draw Through SA Fan, Non-compressorized,
End Control Panel, Left Access
H = Draw Through SA Fan, Non-compressorized,
End Control Panel, Right Access
L = Draw Through SA Fan, Non-compressorized,
Walk-in Vestibule, Left Access
M = Draw Through SA Fan, Non-compressorized,
Walk-in Vestibule, Right Access
N = Blow Through SA Fan, Walk-in Vestibule, Left
Side Access
P = Blow Through SA Fan, Walk-in Vestibule, Right
Side Access
Q = Blow Through SA Fan, Non-compressorized,
End Control Panel, Left Access
R = Blow Through SA Fan, Non-compressorized,
End Control Panel, Right Access
U = Blow Through SA Fan, Non-compressorized,
Walk-in Vestibule, Left Access
V = Blow Through SA, Fan Non-compressorized,
Walk-in Vestibule, Right Access
2: SUPPLY & RETURN LOCATIONS
0 = Bottom Supply--Bottom Return
A = Bottom Supply--No Return
B = Bottom Supply--Left Return
C = Bottom Supply--Right Return
D = Bottom Supply--End Return
E = Left Supply--No Return
F = Left Supply--Bottom Return
G = Left Supply--Left Return
H = Left Supply--Right Return
J = Left Supply--End Return
K = Right Supply--No Return
L = Right Supply--Bottom Return
M = Right Supply--Left Return
N = Right Supply--Right Return
2: SUPPLY & RETURN LOCATIONS
Continued
P = Right Supply--End Return
Q = Top Supply--No Return
R = Top Supply--Bottom Return
S = Top Supply--Left Return
T = Top Supply--Right Return
U = Top Supply--End Return
Feature 3: SUPPLY FAN OPTIONS
3A: SUPPLY FAN QUANTITY
0 = 1 Fan
A = 2 Fans
B = 3 Fans
C = 4 Fans
D = 5 Fans
E = 6 Fans
F = 7 Fans
G = 8 Fans
H = 9 Fans
J = 10 Fans
K = 11 Fans
L = 12 Fans
3B: SUPPLY FAN CONFIGURATION
0 = No VFDs + Full Width Fan
A = 1 Fan per VFD + Full Width Fan
B = 2 Fans per VFD + Full Width Fan
C = 3 Fans per VFD + Full Width Fan
D = 4 Fans per VFD + Full Width Fan
E = No VFDs + Narrow Width Fan
F = 1 Fan per VFD + Narrow Width Fan
G = 2 Fans per VFD + Narrow Width Fan
H = 3 Fans per VFD + Narrow Width Fan
J = 4 Fans per VFD + Narrow Width Fan
K = Option 0 + Inlet Backdraft Dampers
L = Option A + Inlet Backdraft Dampers
M = Option B + Inlet Backdraft Dampers
N = Option C + Inlet Backdraft Dampers
P = Option D + Inlet Backdraft Dampers
Q = Option E + Inlet Backdraft Dampers