13
1.
Startup and service must be performed by
a Factory Trained Service Technician.
2.
Use only with type of the gas approved
for the furnace. Refer to the furnace rating
plate.
3.
The unit is for outdoor use only. See
General Information section for more
information.
4.
Provide adequate combustion ventilatio n
air to the furnace. If a vent duct extension
is used, a class III approved vent is
required. See the Locating Units and Gas
Heating sections of the Installation
section of the manual.
5.
Always install and operate furnace within
the intended temperature rise range and
duct system external static pressure (ESP)
as specified on the unit nameplate.
6.
The supply and return air ducts must be
derived from the same space. It is
recommended ducts be provided with
access panels to allow inspection for duct
tightness. When a down flow duct is used
with electric heat, the exhaust duct must
be an L shaped duct.
7.
Clean furnace, duct, and components
upon completion of the construction
setup.
Verify
furnace
operating
conditions
including
input
rate,
temperature rise, and ESP.
8.
Every unit has a unique equipment
nameplate with electrical, operational,
and
unit
clearance
specifications.
Always refer to the unit nameplate for
specific ratings unique to the model you
have purchased.
9.
READ THE ENTIRE INSTALLATION,
OPERATION, AND MAINTENANCE
MANUAL.
OTHER
IMPORTANT
SAFETY
PRECAUTIONS
ARE
PROVIDED THROUGHOUT THIS
MANUAL.
10.
Keep this manual and all literature
safeguarded near or on the unit.
WARNING