background image

 

 

 

  4. Names

         

 

 

 

 

   

 

 

 

           

 

 

    Front view 

 

 

 

 

  Back view 

 

 

 
 

 

 

 

 
 

 

 

 

 
 

 

 

 

 
 

 

Display

 

 

 

 
 

 

 

 

 

Battery indicator

 

 

The battery indicator changes as the battery capacity decrease 
as shown below: 

               

   

 

Stable indicator

 

 

Displaying weighing data

Turns on when the measurement 

 

value is stable.

 

Internal Settings: Indicates the current setting. 

BT indicator

 

 

Indicates the connection with the measuring instrument. 

Blinking: Indicates during pairing. 
Turn on: Connected to the measuring instrument. 
Turn off: The instrument is not connected to the measuring 

 

instrument.

 

Weighing unit

 

 

Turn on 

 

: Except for the displayable weighing unit .   

 

Key operation 

ON/OFF key 

Turning the power ON/OFF 

SET key 

Press and hold (for about 3 seconds) to go to pairing mode. 
If the connection is disconnected, press the switch once. Attempt to 
connect again. 

SET + ON/OFF key 

Enter the internal setting mode.

Refer to 

"7. Function"

 

 

ON/OFF key 

SET key 

Stand 

Display

 

Wall-mount hole

 

Battery cover

 

Serial number 

USB (Micro-B) 

Battery indicator

 

Stable indicator

 

Polarity

 

BT indicator

 

Weighing unit

 

Summary of Contents for AD-8931

Page 1: ...1WMPD4003853 Wireless Remote Display AD 8931...

Page 2: ...uch marks by A D is under license WARNING Repairs Do not disassemble the device Contact your local A D dealer if your device needs service or repair Troubleshooting If a problem has occurred and you c...

Page 3: ...hese limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio fr...

Page 4: ...ata from the weighing device is displayed The power supply can use four AAA batteries R03 LR03 sold separately or USB power supply Pairing with a weighing device is required to start communication ref...

Page 5: ...ed to the measuring instrument Turn off The instrument is not connected to the measuring instrument Weighing unit Turn on Except for the displayable weighing unit Key operation ON OFF key Turning the...

Page 6: ...B terminal on the side of the main unit CAUTION The USB cable is not included Data transfer from the USB terminal is not possible Operation is not guaranteed with of all power supply units Check the...

Page 7: ...he BT indicator does not light up the power turned off after about 1 minute Repeat from step 1 7 The product is connected to the measuring device If the measuring device s power is disconnected or the...

Page 8: ...p If the BT indicator does not light up turn off the product and the measuring instrument and turn them on again 5 Displays the received measurement data If the measuring device s power is disconnecte...

Page 9: ...3 seconds elapse from the stable indicator lighting up The backlight is always lit in function setting mode Backlight operation 1 Always OFF 2 Auto Clrf Returns the function settings to factory defau...

Page 10: ...t has failed 9 Specification Compatible communication devices A D weighing instruments equipped with Bluetooth 1 Display 7 segment LCD with backlight Character height 26 mm Display update Approximatel...

Page 11: ...etween Bluetooth devices the range of communication will be shorter Interference may be caused near the following devices that use the 2 4 GHz frequency band which is the same as for Bluetooth Therefo...

Page 12: ...550420 Fax 44 1235 550485 A D AUSTRALASIA PTY LTD 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 A D KOREA Limited 6 33 817 07331 817 Manhattan Bld...