![A&D AD-4406A Instruction Manual Download Page 24](http://html1.mh-extra.com/html/aandd/ad-4406a/ad-4406a_instruction-manual_3072994024.webp)
Page
22
AD-4406A
Weighing Indicator
6.2.
F-Functions
Weighing Conditions (Digital filter, Zero tracking and Stability)
Item
Parameter
Description
0
2
d/
1.6s
1
4
d/
1.6s
2
8
d/
1.6s
3 16
d/
1.6s
4 32
d/
1.6s
5 64
d/
1.6s
6 128
d/
1.6s
7
2
d/
3.2s
* 8
4 d/ 3.2s
9
8
d/
3.2s
10 16
d/
3.2s
11 32
d/
3.2s
12 64
d/
3.2s
F00
Filter
Motion / Averaging
time
13 128
d/
3.2s
If a weak filter is set, the
response will be fast, but will be
more sensitive to external
influences such as vibration.
0 OFF
* 1
0.5 d/ 1s
2
1.0
d/
1s
3
1.5
d/
1s
4
2.0
d/
1s
5
2.5
d/
1s
6
0.5
d/
2s
7
1.0
d/
2s
8
1.5
d/
2s
9
2.0
d/
2s
F01
Zero tracking
10
2.5
d/
2s
This function traces the weight
value drifting around the zero
point slowly, displayed as zero.
If a strong parameter is set, a
very small zero drift may be not
detected.
If CF00 is 1, then only 0 or 1
can be selected for F01. (Initial
setting is 1)
0
No motion detection
1
0.5
d/
0.5s
2
1.0
d/
0.5s
3
2.0
d/
0.5s
4
3.0
d/
0.5s
5
4.0
d/
0.5s
6
0.5
d/
1s
7
1.0
d/
1s
* 8
2.0 d/ 1s
9
3.0
d/
1s
F02
STABLE mark
(Motion detection)
condition
10
4.0
d/
1s
The function to set the condition
of judgment whether a weigh
value is unstable or stable. The
ZERO key and TARE key are
active in the stable state. If
these keys need to be active in
the unstable state, select 1 for
CF04.
If CF00 is 1, then only 6 or 7
can be selected for F02. (Initial
setting is 6.)
0 1
(
STABLE
on)
1
Twice in succession
* 2
Three times
F03
Auto print/Auto
accumulation timing
3 Four
times
Set the number of times the
STABLE mark turns on in
succession, before output.
If CF00 is 1, then only 2 or 3
can be selected for F03.
d: division (weighing interval) of the first range
s: second *: Initial
settings
6.2. F-Functions