background image

 

Operators and Maintenance Manual 

 

Display

 

EEM AM4 FE H01

 

Page 

12/19

 

 

Copyright: 

Auto & Aero Technologies Sp. z o.o. 

Mazowiecka 10/5, 20-723 Lublin, Poland  

  email: [email protected] 

   

www.aatech.pl 

 

 

1)

 

by means of the colour of two status diodes according to the 

following colour code: 

a)

 

green

 

 engine parameters within normal range; 

b)

 

orange

 

 warning; 

c)

 

red

 

 alarm; 

2)

 

by means of the colour of digits and bar graph (if applicable) 

presenting the value of the parameter: 

a.

 

green

 

 engine parameters within normal range; 

b.

 

orange

 

 warning; 

c.

 

red

 

 alarm; 

Tab. 2.  Parameters displayed by EEM AM4 FE H01 display 

Lp. 

Parameter 

Symbol/ 

name  

in display 

Unit 

Range of 

bar graph 

indicator 

Warning/alarm thresholds 

Warning 

 

Alarm 

 

Engine speed 

ENGINE 

RPM 

 6000 

rpm 

from 1400 

to 1600 

rpm

#

 

 

from 5500 

to 5800 

rpm 

under 

1400 rpm

 

above 5800 

rpm 

Rotor speed 

ROTOR 

SPEED 

RPM 

 600 

rpm 

from 150 

to 200 rpm 

 

from 400 

to 450 rpm 

under 

150 rpm 

 

above 450 

rpm 

Cylinder head 

temperature 

CHT 

°C

 

 

120°C

 

from 100 

to 

110°C

 

above 

110°C

 

Exhaust gas 

temperature 

EGT 

°C

 

 

900°C

 

under 

500°C

 #

 

 

from 850 

to 900°C

 

above 

900°C

 

Voltage in 

electric 

power 

instalation 

--- 

---- 

from 11 

to 12V 

 

from 14 

to 15V 

under 11V 

 

above 15V 

Summary of Contents for EEM AM4 01 AR02

Page 1: ...anual Display EEM AM4 FE H01 Page 1 19 Copyright Auto Aero Technologies Sp z o o Mazowiecka 10 5 20 723 Lublin Poland email info aatech pl www aatech pl Operators and Maintenance Manual Display EEM AM...

Page 2: ...uction 3 1 General information 4 2 Handling in transport and storage 4 3 Installation 5 3 1 Environmental specifications 5 3 2 Dimensions 5 3 3 Mounting 6 3 4 Power and wiring 7 4 Operation and mainte...

Page 3: ...ed cylinder head temperature exhaust gases temperature voltage flight time hobbs and number of recorded threshold crossings The device is equipped with four an in built colour displays protected by an...

Page 4: ...Operation of this instrument is the sole responsibility of the pilot in command PIC of the aircraft This person must be proficient and carry a valid and relevant pilot s license This person has to mak...

Page 5: ...om water 3 Installation 3 1 Environmental specifications The EEM AM4 display has been designed to be installed in non hermetic cockpits of ultralight aircrafts of ceiling not exceeding 3 000 m 10 000...

Page 6: ...ould be located conveniently within the pilot s view in the control panel in the cockpit The dimensions of the mounting hole to be cut in the panel is 156 x 164 mm It is recommended that the display i...

Page 7: ...ications nominal supply voltage 12V acceptable supply voltage range 8 30V current 340mA The EEM MOT 01 display is connected to the system by four in built MOLEX Ultra Fit 3 5 mm 6 pin male connector l...

Page 8: ...x 0 5mm2 according to DIN VDE 0814 Fig 4 Twisting should continue to the pins of the connector Pins 1 and 2 are to be left unconnected Tab 1 Connector pin assingment and pin insertion view Pin number...

Page 9: ...ay is to be connected to measurement module EMS DAQ R2 The front panel of EEM AM4 is composed of four displays group each with three elements the display two status diodes alert indication and the enc...

Page 10: ...m left quarter of the display c Oil pressure in the upper right quarter of the display d Oil temperature in the bottom right quarter of the display 3 Display C bottom left a Cylinder head temperature...

Page 11: ...lues are listed in Table 2 As the aircraft operates within normal range of the parameter in question the instrument displays values in green and status diodes are green If the threshold level is being...

Page 12: ...in normal range b orange warning c red alarm Tab 2 Parameters displayed by EEM AM4 FE H01 display Lp Parameter Symbol name in display Unit Range of bar graph indicator Warning alarm thresholds Warning...

Page 13: ...0 to 5 C from 50 to 60 C under 0 C above 60 C 11 Oil pressure OIL p Bar 0 7 5 bar from 1 0 to 2 5 bar from 5 0 to 7 0 bar under 1 0 bar above 7 bar 12 Oil temperature OIL T C 0 140 C from 50 to 60 C...

Page 14: ...14 19 Copyright Auto Aero Technologies Sp z o o Mazowiecka 10 5 20 723 Lublin Poland email info aatech pl www aatech pl Fig 7 The idea of flight parameter status information 5 Service diagnostics and...

Page 15: ...b Turn on the power on to check if operational 5 3 Cleaning and conservation The screen is to be buffed with water damped soft cloth Optionally if very dirty can be cleaned with cloth sparingly damped...

Page 16: ...conducted only by its manufacturer The display does not contain any user serviceable parts Unauthorized repairs or modifications may result in permanent damage to the equipment and void the warranty...

Page 17: ...s this product for 12 months from date of purchase 4 Auto Aero Technologies Sp z o o will at its sole option repair or replace any components that fail in normal use Such repairs or replacement will b...

Page 18: ...s not cover claims that arise from the product parameters unless they are different from values declared by Auto Aero Technologies Sp z o o 9 The warranty does not cover activities that belong to norm...

Page 19: ...chnologies Sp z o o and shall not without prior written permission of Auto Aero Technologies Sp z o o be disclosed in whole or in part to third parties This statement shall be included on any reproduc...

Reviews: