3-7
Chapter 3: BIOS setup
Chassis 1 Smart Fan Control [Disabled]
Allows you to enable or disable Chassis 1 Smart Fan Control. Configuration options:
[Enabled] [Disabled]
The following sub-items appear only when you set Chassis 1 Smart Fan Control
to [Enabled].
Fan Out Mode [PWM Mode]
Configuration options: [PWM Mode] [DC Mode]
Fan Control Mode [Manual Mode]
Configuration options: [Manual Mode] [Auto Mode]
PWM/DC Voltage Output [255]
This item appears only when you set the previous item to [Manual Mode] and
allows you to set the voltage allocated for Fan Control. Input value range:
[0~255]
The following items appear only when you set
Fan Control Mode
to [Auto
Mode].
Temperature Source [SYSTIN]
Allows you to select the temperature source. Configuration options: [SYSTIN]
[PECI Agent 0]
Temperature 1~4 [xx]
Input temperature setting. The values range from 0~255.
Fan PWM 1~4 [xx]
Input the amount of Fan PWM 4 for Smart Fan IV Mode. The values range
from 0~255.
Tolerance of Temperature [xx]
Input the tolerance of target temperature. The values range from 0~7.
Critical Temperature [xx]
Determines the time that Fan Out takes to decrease its value by one step.
The values range from 0~255.
Critical Temp Tolerance [xx]
Input the tolerance of critical temperature. The values range from 0~7.