Troubleshooting
The test method for failure of the ozone generator:
• Check the power input for correct voltage (110V or 220V)
• Unit is on, but no ozone; this is due to overheating or water back flow to the ozone
generator.
• Turn off ozone generator and let air flow through the unit for 1 to 2 hours to dry the
ozone tube.
• Check the main fuse, change if needed. It is a 3 AMP for SP-3G to SP-8G and 6 AMP for
the SP-16G fuse.
• Check the tubing inside the machine for kinks.
• If the machine can produce some air, but the air is not ozone; please check the
following:
• The power indication lamp is lit.
• Check ozone control knob is set above zero.
• Check ozone board fuse, 3 AMP.
• Check wire from terminal to ozone board.
• Check pot wire is connected to ozone board.
If you are still experiencing problems, please contact A2Z Ozone for more information.