www.a-ts.cn A-TS Technology
FT50
49
details, please refer to Chapter 6.3
Parameter List
Quick commissioning
parameter mode
Check the parameter function code
of the quick commissioning group
User-defined
parameter mode
Check user-defined parameter
function codes
User setting
parameter mode
Check the parameter function code
that is different from the factory
default
1
)
Basic parameter mode
In the basic parameter mode, all parameter function codes of the frequency converter can
be checked. It can be checked or modified as per the introduction in Chapter 4.2.3. The three
display modes of parameter function codes are switched by the
QUICK
key on the panel. After
entering the display mode, the method of viewing or modifying the each group of parameter
function code is the same as the description in chapter 4.2.3.
2
)
Quick checking modes
Check quick commissioning parameter function code
Press the
QUICK
key on the panel to enter the Quick commissioning parameter mode,
and check the parameter function code of the quick commissioning group. In this mode, it is
convenient for the user to set the matching and basic control parameters of the frequency
converter and the motor, so as to complete the quick commissioning of the frequency
converter.
Check user defined parameter function codes group
Press the
QUICK
key on the panel to enter the user defined parameter mode, and check
the user defined parameter function codes.
User-defined parameter function code: The user can define the commonly used parameter
function codes by setting 29 groups (P9001-P9030) of codes. Up to 30 groups of function
codes can be self-defined. There are 29 groups of function codes can be self-defined by
default, and there is 1 group custom parameter function code (P9001). The user can also
modify the default parameter function codes according to the specific needs. If the set value of
a parameter function code in the 29 groups is 0, it means that the parameter function code is
not defined. If NULL is displayed when the user presses
QUICK
key to enter the menu, it
means that the self-defined menu is empty.
Check the parameter function code that has been set by the user
Press the
QUICK
key on the panel to enter the user setting parameter mode, and check
the parameter function code that is different from the factory default. In this mode, it is
convenient for users to access the modified parameter function codes quickly. In the user
setting parameter function code group, the codes that have been set by the user are listed, in
which the current set value of the code is different from the factory default value. The
parameter function code list is generated by the frequency converter automatically.