IOM D-070-P
11
5.2.
Removing the Pilot
•
Unscrew and remove the Pilot Body [1], [2]
5.2.1. Cleaning of the Air Valve
•
Thoroughly wash and clean the air valve components under clean running water to remove all grime; Pay special attention to
the internal parts.
•
Thoroughly clean the O-ring (replace it if needed [1]. Make sure that the O-ring is correctly seated in its designated groove [2].
1
2
2
1