Fit the cables in the strain relief.
Continue (see section 7.8.4.4).
7.8.4.4
Connecting solar collector
Note
This sensor must be mounted in the solar collector;refer to the solar collector installation
manual.
Connect the sensor (S1) to the water heater as follows:
Connect the sensor to terminal 2 and 4 of J13.
Fit the cables in the strain relief.
Continue (see section 7.8.4.5).
7.8.4.5
Connecting tank sensor
Note
This sensor is already mounted in the tank prior to delivery. The sensor is mounted
between the inlet and outlet of the heat exchanger. However, you must still connect the
lead to the solar heating system controller.
Connect the lead for sensor S2 with the blade connectors to the sensor.
Connect the other end to terminals 2 and 4 of J14.
Fit the cables in the strain relief.
Continue (see section 7.8.4.7).
7.8.4.6
Connecting top tank sensor
Using the blade connectors, connect the sensor S
3
lead to the sensor.
Connect the other end to terminals 1 and 3 of J14.
Fit the cables in the strain relief.
Continue (see section 7.8.4.7).
7.8.4.7
Connecting communication cable
Note
The communication cable must always be connected, otherwise neither the appliance nor
the solar heating system controller will run.
Connect the double connector to J16.
Fit the cable in the strain relief.
Connect the other end of the communication cable to the terminal block of the
appliance. See
connecting communication cable to the appliance (see section 7.8.4.7).
electrical diagram for the appliance.
electrical diagram for the solar heating system.
Connect the optional Q/T-sensor (see section 7.8.4.8).
If you do not need to make any more connections:
Fit the cover over the controller.
3.
4.
n
1.
2.
3.
n
1.
2.
3.
4.
1.
2.
3.
4.
n
1.
2.
3.
-
-
-
4.
5.
-
0311753_SGS_28-120_II_UKUK_V2.0 , 2017-05-03
69
Summary of Contents for SGS-28
Page 6: ...6 ...
Page 13: ...User part 0311753_SGS_28 120_II_UKUK_V2 0 2017 05 03 13 ...
Page 14: ...14 ...
Page 16: ...16 User part ...
Page 18: ...18 User part ...
Page 24: ...24 User part ...
Page 40: ...40 User part ...
Page 41: ...Installation Maintenance and Service part 0311753_SGS_28 120_II_UKUK_V2 0 2017 05 03 41 ...
Page 42: ...42 User part ...
Page 82: ...82 Installation Maintenance and Service part ...
Page 90: ...90 Installation Maintenance and Service part ...
Page 104: ...104 Installation Maintenance and Service part ...
Page 110: ...Fig Dimensions SGS 28 30 50 60 110 Installation Maintenance and Service part ...
Page 112: ...Fig Dimensions SGS 80 100 120 112 Installation Maintenance and Service part ...
Page 121: ...12 8 Declaration of conformity 0311753_SGS_28 120_II_UKUK_V2 0 2017 05 03 121 ...
Page 124: ...124 Installation Maintenance and Service part ...
Page 126: ...126 Installation Maintenance and Service part ...