9
TABLE FOR VENT PIPE LENGTH FOR FPSH/FPCR UNITS
TWO INCH DIAMETER PIPE
**Number of 90° Elbows
**Number of 45° Elbows
Minimum Pipe
Maximum Pipe
One (1)
None
2 Ft.
46 Ft.
One (1)
One (1)
1 Ft.
42 Ft.
Two (2)
None
1 Ft.
38 Ft.
Two (2)
One (1)
1 Ft.
34 Ft.
Three (3)
None
1 Ft.
30 Ft.
Three (3)
One (1)
1 Ft.
26 Ft.
Four (4)
None
1 Ft.
22 Ft.
Four (4)
One (1)
1 Ft.
18 Ft.
THREE INCH DIAMETER PIPE
** Number of 90° Elbows
**Number of 45° Elbows
Minimum Pipe
Maximum Pipe
One (1)
None
2 Ft.
75 Ft.
One (1)
One (1)
2 Ft.
72.5 Ft.
Two (2)
None
1 Ft.
70 Ft.
Two (2)
One (1)
1 Ft.
67.5 Ft.
Three (3)
None
1 Ft.
65 Ft.
Three (3)
One (1)
1 Ft.
62.5 Ft.
Four (4)
None
1 Ft.
60 Ft.
Four (4)
One (1)
1 Ft.
57.5 Ft.
***Five (5)
None
1 Ft.
55 Ft.
***Five (5)
One (1)
1 Ft.
52.5 Ft.
***Six (6)
None
1 Ft.
50 Ft.
** One (1) 90° elbow is equal to two (2) 45° elbows.
*** It is not recommended that more than (4) 90° elbows be used, or a combination of three (3) 90° and two (2) 45° elbows, but as long as the
total length is less than in the chart above, the vent system is acceptable.
Note: For the two inch vent, one (1) 90° elbow is approximately the same as eight (8) feet of pipe. For the three inch vent, one (1) 90° elbow is
approximately the same as five (5) feet of pipe.
TABLE FOR VENT PIPE LENGTH FOR FPST UNITS
TWO INCH DIAMETER PIPE
**Number of 90° Elbows
**Number of 45° Elbows
Minimum Pipe
Maximum Pipe
One (1)
None
2 Ft.
27 Ft.
One (1)
One (1)
1 Ft.
23 Ft.
Two (2)
None
1 Ft.
19 Ft.
Two (2)
One (1)
1 Ft.
15 Ft.
Three (3)
None
1 Ft.
11 Ft.
Three (3)
One (1)
1 Ft.
7 Ft.
Four (4)
None
1 Ft.
3 Ft.
THREE INCH DIAMETER PIPE
** Number of 90° Elbows
**Number of 45° Elbows
Minimum Pipe
Maximum Pipe
One (1)
None
2 Ft.
65 Ft.
One (1)
One (1)
2 Ft.
62.5 Ft.
Two (2)
None
1 Ft.
60 Ft.
Two (2)
One (1)
1 Ft.
57.5 Ft.
Three (3)
None
1 Ft.
55 Ft.
Three (3)
One (1)
1 Ft.
52.5 Ft.
Four (4)
None
1 Ft.
50 Ft.
Four (4)
One (1)
1 Ft.
47.5 Ft.
***Five (5)
None
1 Ft.
45 Ft.
***Five (5)
One (1)
1 Ft.
42.5 Ft.
***Six (6)
None
1 Ft.
40 Ft.
** One (1) 90° elbow is equal to two (2) 45° elbows.
*** It is not recommended that more than (4) 90° elbows be used, or a combination of three (3) 90° and two (2) 45° elbows, but as long as the
total length is less than in the chart above, the vent system is acceptable.
Note: For the two inch vent, one (1) 90° elbow is approximately the same as eight (8) feet of pipe. For the three inch vent, one (1) 90° elbow is
approximately the same as five (5) feet of pipe.