Filling
44
Instruction manual BFM
5
gis
5.1
Filling unvented
installations
To fill the appliance, proceed as follows:
1. Open the stop valve (11) in the hot water pipe and, if present, the stop valves
(4) for the circulation pump (6).
2. Close the drain valve (9).
3. Open the nearest hot water draw-off point (14).
4. Open the stop valve (4) on the cold water side (A) so that cold water flows
into the appliance.
5. Completely fill the appliance. When a full water jet flows from the nearest
draw-off point, the appliance is full.
6. Bleed the entire installation of air, for example by opening all draw-off points.
7. The appliance is now under water supply pressure. There should be no
water coming out of the expansion valve (15), nor the T&P valve (3). If this
does happen, the cause might be:
-
The water supply pressure is greater than the specified 8 bar.
Rectify this by fitting a pressure reducing valve (1).
-
The expansion valve in the protected cold supply setup is defective or
incorrectly fitted.
5.2
Filling vented instal-
lations
To fill the appliance, proceed as follows:
1. Open the stop valve (11) in the hot water pipe and, if present, the stop valves
(4) for the circulation pump (6).
2. Close the drain valve (9).
3. Open the nearest hot water draw-off point (14).
4. Open the stop valve (4) on the cold water side (A) so that cold water flows
into the appliance.
5. Completely fill the appliance. When a full water jet flows from the nearest
draw-off point, the appliance is full.
6. Bleed the entire installation of air, for example by opening all draw-off points.
7. The appliance is now under water supply pressure. There should be no
water coming out of the T&P valve (3). If this does happen, the T&P valve
might be defective or incorrectly fitted.
Summary of Contents for BFM - 100
Page 1: ......
Page 2: ......
Page 4: ...4 Instruction manual BFM gis ...
Page 10: ...Introduction 10 Instruction manual BFM 1 gis ...
Page 16: ...Working principle of the appliance 16 Instruction manual BFM 2 gis ...
Page 42: ...Conversion to a different gas category 42 Instruction manual BFM 4 is ...
Page 48: ...Draining 48 Instruction manual BFM 6 gis ...
Page 52: ...Status of the appliance 52 Instruction manual BFM 8 gis ...
Page 54: ...Starting and running 54 Instruction manual BFM 9 gis ...
Page 56: ...Shutting down 56 Instruction manual BFM 10 gis ...
Page 62: ...is Instruction manual BFM 62 ...
Page 72: ...Electrical diagram 72 Instruction manual BFM 14 is ...
Page 74: ...0306 723 4 0 UK Index Instruction manual BFM ...