Instruction manual BFM
23
is
3.5
Installation diagram
3.5.1
Installation
This figure shows the installation diagram. This diagram is used in the sections
in which the actual connection process is described.
Installation diagram
Legend
Only applicable numbers are
mentioned.
1. pressure reducing valve
(mandatory)
3. T&P valve (mandatory)
4. stop valve (recommended)
5. non-return valve (mandatory)
6. circulation pump (optional)
7. top to bottom circulation pump
(optional)
9. drain valve
10. manual gas valve (mandatory)
11. service stop valve (mandatory)
12. temperature gauge
(recommended)
14. hot water draw-off points
15. expansion valve (mandatory)
16. expansion vessel (mandatory)
17. 3-way aeration valve
(recommended)
18. water tank
19. float valve
A. cold water supply
B. hot water supply
C. circulation pipe
D. gas supply
E. overflow pipe
H. overflow pipe
IMD-0467 R0
UNVENTED
VENTED
B
A
4
18
19
E
H
C
14
11
4
C
4
6
4
5
D
10
9
3
17
12
4
4
7
5
13
C
B
D
9
4
14
14
14
6
5
4
12
3
10
11
A
4
5
1
16
7
4
5
4
15
13
Summary of Contents for BFM - 100
Page 1: ......
Page 2: ......
Page 4: ...4 Instruction manual BFM gis ...
Page 10: ...Introduction 10 Instruction manual BFM 1 gis ...
Page 16: ...Working principle of the appliance 16 Instruction manual BFM 2 gis ...
Page 42: ...Conversion to a different gas category 42 Instruction manual BFM 4 is ...
Page 48: ...Draining 48 Instruction manual BFM 6 gis ...
Page 52: ...Status of the appliance 52 Instruction manual BFM 8 gis ...
Page 54: ...Starting and running 54 Instruction manual BFM 9 gis ...
Page 56: ...Shutting down 56 Instruction manual BFM 10 gis ...
Page 62: ...is Instruction manual BFM 62 ...
Page 72: ...Electrical diagram 72 Instruction manual BFM 14 is ...
Page 74: ...0306 723 4 0 UK Index Instruction manual BFM ...