Installation
36
Instruction manual BFM
3
is
3.11 Checking the supply
pressure and burner
pressure
Note
Before starting the appliance and/or checking the supply pressure and
burner pressure, you must fill
(5 "Filling")
the appliance.
Caution
Before starting up for the first time or after conversion, you must always
check the supply pressure and burner pressure.
Note
The easiest way to check the gas pressures is by using two pressure
gauges. This procedure assumes that these two gauges are available.
If the appliance is to be run on a different gas category than the factory preset
gas category (see type plate) then you must first convert
(4 "Conversion to a
different gas category")
the appliance.
Gas control for BFM 30 through 100
Legend
1. burner pressure regulator
2. burner pressure regulator cap
3. burner pressure regulator
adjustment screw
4. gas control connector
5. blank plate
6. supply pressure test nipple
7. gas control
8. manifold test nipple
1
4
5
6
8
7
2
3
IMD-0256 R1
Summary of Contents for BFM - 100
Page 1: ......
Page 2: ......
Page 4: ...4 Instruction manual BFM gis ...
Page 10: ...Introduction 10 Instruction manual BFM 1 gis ...
Page 16: ...Working principle of the appliance 16 Instruction manual BFM 2 gis ...
Page 42: ...Conversion to a different gas category 42 Instruction manual BFM 4 is ...
Page 48: ...Draining 48 Instruction manual BFM 6 gis ...
Page 52: ...Status of the appliance 52 Instruction manual BFM 8 gis ...
Page 54: ...Starting and running 54 Instruction manual BFM 9 gis ...
Page 56: ...Shutting down 56 Instruction manual BFM 10 gis ...
Page 62: ...is Instruction manual BFM 62 ...
Page 72: ...Electrical diagram 72 Instruction manual BFM 14 is ...
Page 74: ...0306 723 4 0 UK Index Instruction manual BFM ...