S14 (blocking error)
Short circuit in flue gas
sensor 1
Short circuit in flue gas
sensor circuit
Replace the flue gas sensor
(2)
and lead.
To replace the necessary parts, you must contact your installation
engineer
S15 (blocking error)
Short circuit in flue gas
sensor 2
Short circuit in flue gas
sensor circuit
Replace the flue gas sensor
(2)
and lead.
To replace the necessary parts, you must contact your installation
engineer
F01 (blocking error)
Defect in power supply
circuit
Live and neutral
connected wrong way
round
Connect live and neutral correctly (3.10 "Electrical connection");
the appliance is phase-sensitive
See the ADMR electrical diagram (17 "Appendices")
Condensation on the
flame probe
1. Disconnect the lead at the flame probe
2. Ignite the appliance three times, with an interrupted ionisation
circuit
3. Reconnect the ionisation lead to the flame probe
4. Ignite the appliance again
5. The repeated ignition attempts will have caused the
condensation to evaporate
If errors persist, contact your installation engineer
Floating neutral
Install an isolating transformer (3.10.5 "Connecting an isolating
transformer")
Contact your installation engineer to have an isolating transformer
installed
Symptom
Cause
Solution
Remark
Summary of Contents for ADMR - 40
Page 4: ...4 Instruction manual ADMR gis ...
Page 10: ...Introduction 10 Instruction manual ADMR 1 gis ...
Page 54: ...Shutting down 54 Instruction manual ADMR 10 gis ...
Page 62: ...Main menu 62 Instruction manual ADMR 11 gis ...
Page 76: ...is Instruction manual ADMR 76 ...
Page 78: ...Maintenance frequency 78 Instruction manual ADMR 14 is ...
Page 84: ...Performing maintenance 84 Instruction manual ADMR 15 s ...
Page 92: ...Appendices 92 Instruction manual ADMR 17 is ...
Page 94: ...Instruction manual ADMR 94 ...