Installation diagram
Release R.1.3 UK
23
is
Table 3.6
Gas data
3.5
Installation diagram
Figure 3.3
shows the water and gas connection diagrams for unvented and
vented installations. The following paragraphs, describing the connections in
detail, make reference to these diagrams
Gas category data
II
2H3+
Unit
BFC 28
BFC 30
BFC 50
BFC 60
Data for natural gas 2H: G20-20 mbar
Orifice diameter
mm
4.90
5.10
7.00
7.10
Nominal load (upper value)
kW
32.1
34.5
52.6
63.2
Nominal capacity
kW
30.3
32.8
48.6
59.6
Supply pressure
mbar
20
20
20
20
Burner pressure
mbar
8.5
8.5
8.5
11.5
Gas consumption
(1)
m
3
/h
3.1
3.3
5.0
6.0
Data for LP gas 3+
General
Orifice diameter
mm
2.50
2.60
3.40
3.80
Restrictor diameter
mm
n.a.
n.a.
n.a.
n.a.
G30-30 mbar (butane)
Nominal load (upper value)
kW
30.7
32.8
50.6
59.4
Supply pressure
mbar
37
37
37
37
Burner pressure
(2)
mbar
37
37
37
37
Gas consumption
(1)
kg/h
2.2
2.4
3.7
4.3
G31-37 mbar (butane)
Nominal load (upper value)
kW
29.0
30.9
50.3
59.1
Supply pressure
mbar
37
37
37
37
Burner pressure
(2)
mbar
37
37
37
37
Gas consumption
(1)
kg/h
2.1
2.2
3.6
4.2
(1) Based on 1013.25 mbar and 15
o
C.
(2) If using a flat sealing plate instead of a burner pressure regulator, it is assumed that the burner pressure is equal to the supply pressure.
In practice however, the burner pressure will be lower.
Summary of Contents for 28 30 50 60
Page 2: ...your installer www aosmithinternational com...
Page 4: ...4 Instruction Manual BFC...
Page 12: ...Introduction 12 Instruction Manual BFC 1 gis...
Page 38: ...Installation 38 Instruction Manual BFC 3 is...
Page 42: ...Filling and draining 42 Instruction Manual BFC 4 gis...
Page 48: ...Status of the appliance 48 Instruction Manual BFC 6 gis...
Page 64: ...Main menu 64 Instruction Manual BFC 8 gis...
Page 68: ...Service program 68 Instruction Manual BFC 9 is...
Page 84: ...Maintenance frequency 84 Instruction Manual BFC 11 gs...
Page 94: ...Release R 1 3 UK 94...