Installation
26
Instruction Manual BFC
3
is
3.7
Water connections,
Vented
3.7.1
Cold water side
See
a
in
Figure 3.3
.
1. Fit an approved stop valve
i
on the cold water side between the water
cistern
n
and the appliance, as required by regulations. Refer also to
paragraph
’1.3 Regulations’
.
3.7.2
Hot water side
See
b
in
Figure 3.3
.
n
Remark
Insulating long hot water pipes prevents unnecessary energy loss.
1. Fit the T&P valve
c
.
2. Optional: fit a temperature gauge
j
to be able to check the temperature of
the tap water.
3. Fit a stop valve
i
in the hot water outlet pipe, for use when servicing.
4. If a circulation pipe is to be fitted, then refer to paragraph
3.7.3
.
3.7.3
Circulation pipe
See
c
in
Figure 3.3
.
If an immediate flow of hot water is required at draw-off points, a circulation
pump can be installed. This improves comfort and reduces water wastage.
1. Fit a circulation pump
f
of the correct capacity for the length and resistance
of the circulation system.
2. Fit a non-return valve
e
behind the circulation pump to guarantee the
direction of circulation.
3. Fit two stop valves
d
for service purposes.
4. Connect the circulation pipe to the cold water supply pipe.
3.7.4
Condensation drainage
See paragraph
’3.6.4 Condensation drainage’
.
3.8
Gas connection
Warning
Gas installation may only be carried out by an authorised installer in
compliance with the general regulations imposed by the gas company.
Refer also to paragraph
’1.3 Regulations’
.
c
Note
Make sure that the diameter and length of the gas supply pipe are large
enough to supply sufficient capacity to the appliance.
See
d
in
Figure 3.3
.
1. Fit a gas valve
h
in the gas supply pipe.
2. Blow the gas pipe through before use, to be sure it is clean.
3. Close the gas valve.
Summary of Contents for 28 30 50 60
Page 2: ...your installer www aosmithinternational com...
Page 4: ...4 Instruction Manual BFC...
Page 12: ...Introduction 12 Instruction Manual BFC 1 gis...
Page 38: ...Installation 38 Instruction Manual BFC 3 is...
Page 42: ...Filling and draining 42 Instruction Manual BFC 4 gis...
Page 48: ...Status of the appliance 48 Instruction Manual BFC 6 gis...
Page 64: ...Main menu 64 Instruction Manual BFC 8 gis...
Page 68: ...Service program 68 Instruction Manual BFC 9 is...
Page 84: ...Maintenance frequency 84 Instruction Manual BFC 11 gs...
Page 94: ...Release R 1 3 UK 94...