![A.O. Smith 120 through 250 Series Installation, User And Service Manual Download Page 35](http://html.mh-extra.com/html/a-o-smith/120-through-250-series/120-through-250-series_installation-user-and-service-manual_447391035.webp)
Instruction manual BFC
33
is
Practical example of parallel flue gas discharge
Example
The figure shows a BFC 30 installation. This has to be fitted with a 10 m parallel
pipe of 100 mm diameter, and eight 90 degree bends. The configuration must
be checked for compliance with the requirements stated in the table.
Appliance with parallel flue gas discharge material
The longest pipe must be used to check the maximum length. In this case, the
chimney pipe is the longest. This is 10 metres. This 10 metres is the sum of pipe
sections 1, 2, 3, 4 and 5. The length of the transition piece can be ignored. The
total number of bends used
in the flue gas discharge and air supply
is 8. The
bend in the transition piece can be ignored. According to the table, 4.6 metres
must be added for each bend. This brings the total pipe length to:
(4.6 x 8) + 10 = 36.8 + 10 = 46.8 m.
This is less than the maximum length of 55 metres stated in the table. The
installation therefore fulfils the requirements.
3.10 Electrical
connection
Warning
The installation should be carried out by a competent person, in compliance
with general and locally applicable regulations (1.3 "Regulations").
3.10.1
Introduction
This section covers the following topics:
•
Preparation;
•
Connecting the mains power;
Optionally, it is possible to connect an isolating transformer, a continuous pump,
a program-controlled pump, an extra ON mode switch and an extra alarm signal
to the water heater. For these options, see:
•
Isolating transformer;
•
Connecting a program-controlled pump;
•
Connecting an extra ON mode switch
Note
The optional components are not included in the electrical power
consumption rating stated in the table (3.4.2 "General and electrical
specifications").
Summary of Contents for 120 through 250 Series
Page 4: ...E2 ...
Page 6: ...4 Instruction manual BFC gis ...
Page 10: ...Contents 8 Instruction manual BFC ...
Page 31: ...Instruction manual BFC 29 is Installation types IMD 0789 R0 C43 C13 C53 B23 C33 ...
Page 48: ...Conversion to a different gas category 46 Instruction manual BFC 4 is ...
Page 58: ...Status of the water heater 56 Instruction manual BFC 8 gis ...
Page 62: ...Shutting down 60 Instruction manual BFC 10 gis ...
Page 74: ...Service program 72 Instruction manual BFC 12 is ...
Page 88: ...Service interval 86 Instruction manual BFC 14 is ...
Page 97: ...Instruction manual BFC 95 is ...
Page 102: ...Instruction manual BFC 100 ...