![A.O. Smith 120 through 250 Series Installation, User And Service Manual Download Page 24](http://html.mh-extra.com/html/a-o-smith/120-through-250-series/120-through-250-series_installation-user-and-service-manual_447391024.webp)
22
Instruction
m
anu
al
BFC
3.4.2
General and electrical specifications
DESCRIPTION
Unit
BFC 28
BFC 30
BFC 50
BFC 60
BFC 80
BFC 100
BFC 120
Contents
litres
217
368
368
368
480
480
480
Empty weight
kg
177
214
214
214
480
480
480
Maximum floor load
kg
394
582
582
582
960
960
960
Maximum operating pressure (vented)
kPa (bar)
800 (8)
800 (8)
800 (8)
800 (8)
800 (8)
800 (8)
800 (8)
Maximum operating pressure (unvented)
kPa (bar)
550 (5,5)
550 (5,5)
550 (5,5)
550 (5,5)
550 (5,5)
550 (5,5)
550 (5,5)
Control thermostat adjustment range
o
C
40…80
40…80
40…80
40…80
40…80
40…80
40…80
Control thermostat and default value
o
C
65
65
65
65
65
65
65
Adjustment range for hysteresis upwards
o
C
0…5
0…5
0…5
0…5
0…5
0…5
0…5
Default value for hysteresis upwards
o
C
5
5
5
5
5
5
5
Adjustment range for hysteresis downwards
o
C
0…10
0…10
0…10
0…10
0…10
0…10
0…10
Default value for hysteresis downwards
o
C
5
5
5
5
5
5
5
Number of (electrical) anodes
-
1
2
2
2
2
2
2
Observed pressure differential across the pressure
switch
Pa
≥
165
≥
165
≥
165
≥
165
≥
260
≥
260
≥
260
Pressure differential to open the pressure switch
Pa
< 115
< 115
< 115
< 115
< 210
< 210
< 210
Heating time
Δ
T = 45°C
at least
22
35
23
19
18
15
12
DESCRIPTION
Unit
BFC 28
BFC 30
BFC 50
BFC 60
BFC 80
BFC 100
BFC 120
Electrical power consumption
W
45
45
75
115
95
145
240
Supply voltage (-15% +10% VAC)
volts
230
230
230
230
230
230
230
Mains frequency (± 1Hz)
Hz
50
50
50
50
50
50
50
IP class
-
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
Summary of Contents for 120 through 250 Series
Page 4: ...E2 ...
Page 6: ...4 Instruction manual BFC gis ...
Page 10: ...Contents 8 Instruction manual BFC ...
Page 31: ...Instruction manual BFC 29 is Installation types IMD 0789 R0 C43 C13 C53 B23 C33 ...
Page 48: ...Conversion to a different gas category 46 Instruction manual BFC 4 is ...
Page 58: ...Status of the water heater 56 Instruction manual BFC 8 gis ...
Page 62: ...Shutting down 60 Instruction manual BFC 10 gis ...
Page 74: ...Service program 72 Instruction manual BFC 12 is ...
Page 88: ...Service interval 86 Instruction manual BFC 14 is ...
Page 97: ...Instruction manual BFC 95 is ...
Page 102: ...Instruction manual BFC 100 ...